32
[010] PC5208 PGM Output Programming (PGM 3-10)
(Section 5.11 “PGM Output Options” )
Default
Default
01
I_______I_______I
PGM 3
01
I_______I_______I
PGM
7
01
I_______I_______I
PGM 4
01
I_______I_______I
PGM 8
01
I_______I_______I
PGM 5
01
I_______I_______I
PGM 9
01
I_______I_______I
PGM 6
01
I_______I_______I
PGM 10
Program PGM Option Attributes in sections [143] - [150].
[011] PC5204 PGM Output Programming (PGM 11-14)
(Section 5.11 “PGM Output Options” )
Default
Default
01
I_______I_______I
PGM 11
01
I_______I_______I
PGM
13
01
I_______I_______I
PGM 12
01
I_______I_______I
PGM 14
Program PGM Option Attributes in sections [151] - [154].
[012] Keypad Lockout Options
(Section 5.21 “Keypad Lockout Options” )
NOTE:
If Keypad Lockout is active, the panel cannot be dis-
armed with a keyswitch.
Default
000
I_______I_______I_______I
Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I
Lockout Duration (001-255 minutes)
[013] First System Option Code
Default Option
ON
Off
Section
OFF
I________I
1
Normally
Closed
Loops
End-of-Line
Resistors
2.11
OFF
I________I
2
Double
End-of-Line
Resistors
Single
End-of-Line
Resistors
2.11
ON*
I________I
3
Panel Shows All Troubles When Armed Panel Shows Only Fire Troubles When Armed
3.4
OFF
I________I
4
Tampers/Faults Do Not Show As Open
Tampers/Faults Show As Open
3.4
OFF
I________I
5
For
Future
Use
ON
I________I
6
Audible
Exit
Fault
Enabled
Audible
Exit
Fault
Disabled
5.18
ON
I________I
7
Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past Shutdown
5.20
OFF
I________I
8
Temporal Three Fire Signal Enabled**
Standard Pulsed Fire Signal
5.13
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
**
The Temporal Three Fire Signal
option must be used for UL Household Fire installations.
[014] Second System Option Code
Default Option
ON
Off
Section
OFF
I________I
1
Arm / Disarm Bell Squawk enabled
Arm / Disarm Bell Squawk disabled
5.17
OFF
I________I
2
Bell Squawk During Auto Arm
No Bell Squawk During Auto Arm
5.18
OFF
I________I
3
Bell Squawk On Exit Delay
No Bell Squawk On Exit Delay
5.18
OFF
I________I
4
Bell Squawk On Entry Delay
No Bell Squawk On Entry Delay
5.18
OFF
I________I
5
Bell Squawk On Trouble
No Bell Squawk On Trouble
3.4
ON
I________I
6
Audible Exit with Urgency
Silent Exit Delay
5.18
OFF
I________I
7
Exit Delay Termination Enabled
Exit Delay Termination Disabled
5.18
OFF
I________I
8
Fire Bell is Continuous
Fire Bell Follows Bell Cut-off
5.13