[001]-[005] Function Key Assignments
Section
Function
Key
Button
Valid
Range
Default
Function
[001]
1
00-68
03
Stay Arm
|____|____|
[002]
2
00-68
04
Away Arm
|____|____|
[003]
3
00-68
06
Chime ON/OFF |____|____|
[004]
4
00-68
22
Comm Output 2 |____|____|
[005]
5
00-68
16
Quick Exit
|____|____|
Keypad Function Keys
Please see your system installation manual for more details on the function key options:
[00] - Null
[17] - Arm Interior
[39] -Trouble Display
[02] - Instant Stay Arm
[21] - Command Output 1
[40] - Alarm Memory
[03] - Stay Arm
[22] - Command Output 2
[61] - Partition Select 1
[04] - Away Arm
[23] - Command Output 3
[62] - Partition Select 2
[05] - [*][9] No-Entry Arm
[24] - Command Output 4
[63] - Partition Select 3
[06] - Chime ON/OFF
[29] - Bypass Group Recall
[64] - Partition Select 4
[07] - System Test
[31] - Local PGM Activate
[65] - Partition Select 5
[09] - Night Arm
[32] - Bypass Mode
[66] - Partition Select 6
[12] - Global Stay Arm
[33] - Bypass Recall
[67] - Partition Select 7
[13] - Global Away Arm
[34] - User Programming
[68] - Partition Select 8
[14] - Global Disarming
[35] - User Functions
[16] - Quick Exit
[37] -Time and Date Program
Keypad Programming
Press [*][8][Installer Code]
[860] Keypad Slot Number
This is not for programming; the two-digit slot number is displayed for informational purposes only.
[861]-[876] Keypad Programming Sections
Sections [861]-[876] apply to keypad slot numbers 1-16 accordingly. After selecting the appropriate
keypad section number, the following programming options are available:
[000] Address of Partition
On selecting [000], a 2-digit entry is required to assign the keypad to a partition. Valid entries are 01-
08. The default is 01. NOTE:The HS2LCDWF keypad cannot be assigned as a global keypad.
[001]-[005] Function Key 1- 5 Assignment
[011] Keypad Input/Output Programming
Zone or PGM Number
000
|______|______|______|
[012] Local PGM Output Pulse Activation Time
|_____|_____| Minutes (00-99); |_____|_____| Seconds (00-99)
[021] First Keypad Options
Default
Opt.
ON
OFF
ON
|______|
1
Fire Key Enabled
Fire Key Disabled
ON
|______|
2
Medical Key Enabled
Medical Key Disabled
ON
|______|
3
Panic Key Enabled
Panic Key Disabled
ON
|______|
4
Display Access Code When
Programming
Display X’s When Programming
Access Codes
OFF
|______|
5
For Future Use
For Future Use
OFF
|______|
6
For Future Use
For Future Use
OFF
|______|
7
For Future Use
For Future Use
OFF
|______|
8
For Future Use
For Future Use
NOTE: For EN50131-1/EN50131-3 compliant systems, section [021]: options 1 and 2 shall be OFF.
[022] Second Keypad Options
Default
Opt.
ON
OFF
ON
|______|
1
Local Clock Display ON
Local Clock Display OFF
OFF
|______|
2
Local Clock Displays 24-hr Time Local Clock Displays AM/PM
ON
|______|
3
Auto Alarm Scroll ON
Auto Alarm Scroll OFF
OFF
|______|
4
For Future Use
For Future Use
OFF
|______|
5
Power LED Enabled
Power LED Disabled
ON
|______|
6
Power LED AC Present ON
Power LED AC Present OFF
ON
|______|
7
Alarms Displayed While Armed
Alarms Not Displayed While Armed
OFF
|______|
8
Auto-Scroll Open Zones ON
Auto-Scroll Open Zones OFF
[023] Third Keypad Options
Default
Opt
ON
OFF
OFF
|______| 1
Armed LED On in Sleep Mode
Armed LED Off in Sleep Mode
ON
|______| 2
Keypad Status Shows Stay Arm
Keypad Status Shows Stay/Away Arm
OFF
|______| 7
Temperature Display Enabled
Temperature Display Disabled
Programming options indicated in GREY are required for systems compliant with EN50131-1 and
EN50131-3 standards. Section [023]: 1=OFF
[030] LCD Message
|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|
NOTE: Clock display (Section [022], Option 1) must be enabled.
[031] Downloaded LCD Message Duration
Default: 000 |______|______|______| (Valid entries are 000-255), 000=Unlimited Message Display.
This number represents the number of times the downloaded message must be cleared before it is per-
manently removed. Press any key to delete message.
[041] Indoor Temperature Zone Assignment
Default: 000 |______|______|______| (Valid entries are 000-128)
[042] Outdoor Temperature Zone Assignment
Default: 000 |______|______|______| (Valid entries are 000-128)
[101]-[228] Door Chime for Zones 1-128
The keypad can be programmed to make up to four different chime sounds for individual zones. (e.g.,
for Zone 1, enter Section [101], for Zone 2 enter Section [102]). Default: 01 |_____|_____|