APPENDICES
70
D-306232 WP8010/WP8030 V18 DSC EN USER
WP Panel
WP Panel
Caution!
Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Note:
For compliance with CE standards the
battery capacity must be at least 1300 mAh.
(1) The external devices must be connected
between 12V and ground. The current for
each specified backup period can be
drawn from the batteries with the internal
GSM and the proximity reader connected
to the WP Panel.
(2) 7.2V 1300 mAh, rechargeable NiMH
battery pack, p/n 130AAM6BMX,
manufactured by GP or p/n LTT-
AA1300LSDX6B, manufactured by LTT.
(3) 9.6V 1800 mAh, rechargeable NiMH
battery pack, p/n GP180AAH8BMX,
manufactured by GP or p/n LTT-
AA1800LSDX8B, manufactured by LTT.
(4) 9.6V 2200 mAh, rechargeable NiMH
battery pack p/n 220AAH8BMX,
manufactured by GP or p/n LTT-
AA2200LSDX8B, manufactured by LTT.
Caution!
Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Notes:
1.
For compliance with CE standards the battery
backup period must be at least 12 hours.
2.
For compliance with UL standards the battery
backup period must be at least 24 hours.
Note:
Only the LTT-AA2200LSDX8B battery
pack is approved for use by UL.
Time to Charge
80 % (
13 Hrs)
80 % (
30 Hrs) for all battery types
Optional Backup
Battery Pack
See "Backup Battery Options" above
See "Backup Battery Options" table above
Time to Charge
(optional backup
battery pack)
80 % (
24 Hrs)
NA
Wired Detectors
Total (Sum)
Current
NA
36* mA max.
Site External Siren
Current (EXT)
NA
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
Site Internal Siren
Current (INT)
NA
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
*
Total WP Panel output current (of INT &
EXT sirens, PGM output and detectors) cannot
exceed 550 mA.
PGM
Current sink to control panel GND 100 mA
max.
Max. external DC v30 VDC
Current sink to control panel GND 100 mA
max.
Max. external DC v15 VDC
High Current /
Short Circuit
Protection
NA
All outputs are protected (automatic reset fuse)
E4. Communication
WP Panel
WP Panel
Communication
PSTN; GSM; GPRS; IP (for future use)
PSTN; GSM; GPRS; IP (for future use)
Built-in Modem
300 baud, Bell 103 protocol
300 baud, Bell 103 protocol
Data Transfer to
Local Computer
Via RS232 serial port
Via RS232 serial port
Report
Destinations
2 Monitoring Stations, 4 private telephones
2 Monitoring Stations, 4 private telephones
Reporting Format
SIA, Contact ID, Scancom, SIA IP, DSC
SIA, Contact ID, Scancom, SIA IP, DSC