VISUAL INDICATIONS, FIRST KEYPAD
ENROLLMENT AND USING PROX TAG
4.1 WP8033 LED Indications
The following table provides a detailed description of the LED indications on the WP8033 panel.
Color
Definition
LED Operation
Green
Local Power indication
STEADY:
Indicates that system has mains power
BLINKING:
Low battery state
NO LIGHT:
AC failure
Green
Ready / Not Ready
Indication
STEADY:
All partitions are ready
NO LIGHT:
Not Ready / at least one partition is Not Ready
Red
System Arming State
Indication
STEADY:
AWAY / At least one partition is AWAY
BLINKING:
HOME / At least one partition is HOME and no
partitions are in AWAY
NO LIGHT:
The system is presently in the disarmed state
Orange
System Not Online
Indication
STEADY:
System is unavailable (Sync/Updating/In-menu)
NO LIGHT:
System is available
Orange
System Trouble indication
STEADY:
System has trouble
NO LIGHT:
No trouble – all is well
4.2 Enrollment of the First Keypad
The WP8033 is designed to operate wirelessly with the keypad installed anywhere within the protected premises.
The first keypad is always enrolled as Keypad no. 1.
Note:
The enrolment procedure described here is for the first keypad only. The enrolment of additional keypads is
performed via the first enrolled keypad (for instructions, refer to the keypad Installer’s Guide, section 3.4.2).
Step
Action
1
Press the "ENROLL" button (physically located inside the front unit of the WP8033 control panel – see
Figure 3.1) for 2 seconds. If no keypad exists in the first location, the "ENROLL" LED on the WP8033 blinks
slowly for 1 minute (go to step 3).
If a keypad already exists in the first location, the "ENROLL" LED on the WP8033 control panel lights
steady for 10 seconds (go to step 2).
Note:
Pressing the "ENROLL" button takes the system out of any menu mode (Installer Mode, User
Settings and Periodic Test).
2
Press the "ENROLL" button again within the timeout period (10 seconds). Any keypad that was enrolled in
keypad no. 01 is deleted from the system.
The "ENROLL" LED on the WP8033 blinks slowly for 1 minute.
3
During this 1 minute period, hold the
button for 5-7 seconds, until the
LED on the keypad lights
red, and release
*
. The "ENROLL" LED on the WP8033 will indicate the result of the enrollment procedure.
WP8033 "ENROLL" LED indication
Result
Blinks fast for 5 sec.
Successful enrollment of keypad
Lights steadily for 5 sec.
Wrong device type
4
Upon completion of the enrolling procedure, the keypad is ready for immediate use even if the system is
currently in the Armed state.
Note:
If the keypad was previously enrolled, it will be relocated automatically to Keypad no. 1. However, all
of the configured parameters will be lost and the keypad will revert to the default parameters
.
*
If the keypad is battery-powered:
first press any button on the keypad momentarily to take the keypad out of sleep mode and then
hold the
button for 5-7 seconds, until the
LED on the keypad lights red, and release.