SAFETY INSTRUCTIONS for WS4920 WIRELESS REPEATER

IMPORTANT:

This equipment, WS4920 WIRELESS REPEATER 1.0, shall be installed and used within an 

environment that provides the pollution degree max 2 and overvoltages category II NON 

HAZARDOUS LOCATIONS, indoor only. The equipment is FIXED and DIRECT PLUG IN powered 

from the mains; it is designed to be installed by Service Persons only; Service Person is defined as a 

person having the appropriate technical training and experience necessary to be aware of hazards to 

which that person may be exposed in performing a task and of measures to minimize the risks to that 

person or other persons. 

1. The equipment is installed in a FIRE ENCLOSURE.

2. If during the installation a knockout is removed, it is the installer's responsibility to ensure that 

the same degree of protection for the enclosure is provided by the use of bushings, fittings, etc.

3. The enclosure must be secured to the building structure before operation.

4. Internal wiring must be routed in a manner that prevents:

• Excessive strain on wire and on terminal connections

• Loosening of terminal and connections

• Damage of conductor insulation

5. The end-user and/or installer are responsible for ensuring that the disposal of the used batteries 

(battery pack) is made according to the waste recovery and recycling regulations applicable to 

the intended market.

WARNING: When using equipment connected to the MAINS, always follow basic safety instructions. 

Refer to the SAFETY INSTRUCTIONS provided with this product; save them for (future) reference. 

Instruct the end-user regarding the safety precautions that shall be observed when operating this equipment.

SAFETY precautions required during installation:

• NEVER install this equipment during a lightning storm!

• NEVER touch uninsulated wires or terminals unless the direct plug in transformer has been dis-

connected. 

• Ensure that cables are positioned so that accidents cannot occur. Connected cables must NOT be 

subject to excessive mechanical strain.

• Use only the power supply provided with this equipment. Use of unauthorized power supplies 

may damage the WS4920.

• The AC socket/outlet powering the equipment shall be located near the equipment and shall be 

easily accessible. 

• Do NOT locate this product where persons will walk on the secondary circuit cable(s). 

• Do NOT use extension cords to plug in the power supply of this equipment.

• AVOID setting up the equipment near heaters, air conditioners, ventilators, and/or refrigerators 

• Do NOT connect to electrical outlets on the same circuit as large appliances.

• Do NOT select a place exposed to direct sunlight, excessive heat, moisture, vapors, chemicals or 

dust.

• Do NOT install this Equipment near water. (e.g., bath tub, wash bowl, kitchen/laundry sink, in a 

wet basement, or near swimming pool, etc.).

• Do NOT install this equipment and its accessories in areas where there is a risk of explosion.

• Do NOT connect this equipment to electrical outlets controlled by wall switches or automatic 

timers; avoid interference sources.

WARNING: THIS EQUIPMENT HAS NO MAINS ON/OFF SWITCH. THE PLUG OF THE DIRECT 

PLUG-IN POWER SUPPLY IS INTENDED TO SERVE AS THE DISCONNECTING DEVICE IF THE 

EQUIPMENT MUST BE QUICKLY DISCONNECTED. IT IS IMPERATIVE THAT ACCESS TO THE 

MAINS PLUG AND ASSOCIATED MAINS SOCKET/OUTLET IS NEVER OBSTRUCTED.

Summary of Contents for WS4920

Page 1: ...uipment is intended to be used WARNING READ and SAVE These Instructions Follow All WARNINGS AND INSTRUCTIONS specified within this document and or on the equipment WS4920 v1 0 Installation Instructions Instructions d installation Instrucciones de Instalación Instruções de Instalação Istruzioni di installazione ...

Page 2: ...Instruct the end user regarding the safety precautions that shall be observed when operating this equipment SAFETY precautions required during installation NEVER install this equipment during a lightning storm NEVER touch uninsulated wires or terminals unless the direct plug in transformer has been dis connected Ensure that cables are positioned so that accidents cannot occur Connected cables must...

Page 3: ...0 433 PC4010 433 SCW9055 57 D G I 433 ULRF5132 433 UL RFK5500 433 UL RFK5501 433 UL RFK5508 433 UL RFK5516 433 UL RF4164 433 PC5132 433 RF5108 433 RF5501 433 Motion Detector Wireless Key Smoke Detector UL WLS914 433 ULWS4904 P WS4904M UL WS4939 WS4949 WS4959 WS4969 WS4979 UL WS4916 ULWS4926 Glassbreak Detector CO Detector Hold Up Alarm ULWLS912L 433 WS4913 WLS928 433 Shock Sensor Flood Sensor Pani...

Page 4: ...to the local authorities Secondary 16VAC 18VAC 20VA The following plug in transformers shall be used USA PTD1620U UL CC5 efficiency level IV 16 5V 20VA UL listed installations Canada PTD1620N C UL certified 16 5V 20VA ULC listed installations Europe PTD1620T EU CE approved 230V 16 5V 20VA Maximum allowed wire run distances Only UL listed devices can be used in UL Commercial Burg listed installatio...

Page 5: ...tions Introduction One WS4920 rechargeable Ni MH battery included One direct plug in transformer Not included in all configurations Mounting hardware pack including plastic wall plugs and screws Installation instructions The WS4920 has three LEDs on the front The meaning of these LEDs is different when in normal operational mode cover on than when in Installer mode cover off See the table below fo...

Page 6: ...rking method If the selected location fails the placement test the device must be repositioned Step 2 Connecting Power Connect back up battery first then AC To connect the battery 1 Gently open front cover using small slotted screwdriver in holes provided see Figure 3 The WS4920 includes a Programming button used to place it into Enroll Placement modes A 4 position DIP switch is also provided to s...

Page 7: ...ake several hours to clear To connect the AC adaptor 1 Run AC wire through channel on back of WS4920 and pass through hole in enclosure 2 Connect AC wires to terminals on PC board see Figure 4 3 Route wire around retaining bracket to secure 4 Plug AC adaptor into wall outlet Figure 3 Removing the Cover Figure 4 Power Connections Figure 5 Wire Routing AC Terminals Battery Connector ...

Page 8: ...ation manual NOTE For PowerSeries Alexor MAXSYS and SCW9045 47 use the serial number beginning with 2 For the Impassa SCW9055 SCW9057 use the serial number beginning with A NOTE For non UL listed installations Non alarm zone type 26 is recommended With this zone type loss of AC or a low battery condition are not reported to the central station The alarm panel does not show a trouble for the zone b...

Page 9: ...y be enrolled with one WS4920 The only exception is in UL ULC Residential Fire installations where smoke and CO detectors that are enrolled with a WS4920 must be enrolled with at least two WS4920 s Fobs and panic pendants may be enrolled with multiple WS4920 s If an enrollment is attempted after all 164 device slots have been filled the WS4920 emits a 2 second error tone and all three LEDs light f...

Page 10: ...ough mounting holes using all 4 wall plugs and screws provided 3 Place cover back on WS4920 4 Plug AC adaptor into unswitched AC outlet Restoring the WS4920 to Factory Defaults To restore factory default settings 1 Within 1 minute of power up press and hold Programming button for 10 seconds Sounder beeps after first second to indicate WS4920 is in Installer mode After 10 seconds WS4920 emits doubl...

Reviews: