Section 3: Operation
To use the Emergency keys:
1. Press the Shift key (↑). The Emergency keys are illuminated (if enabled ). If an Emergency key is not pressed within
10 seconds, the keypad returns to normal operating mode.
2. Press and hold an Emergency key for 2 seconds to activate the alarm.
3.1.3 WPS Mode ([*]8)
WPS (Wi-Fi Protected Setup) mode activates iotega‘s Wi-Fi access point to facilitate connection with IP devices, such as the
touchscreen keypad and IP cameras.
To enable WPS mode:
1. Tap [*] 8 on the integrated kaypad.
2. Enter a valid installer code.The WiFi siganl strength LED flashes to indicate the system is in WPS mode.
The WPS window expires after 2 minutes or once an IP address is obtained.
Note:
The Wi-Fi Client enable/disable option has priority over WPS Mode.
3.2 Arming and Disarming Methods
This section describes the arming methods available on the iotega.
3.2.1 Away Arming
Away Arming arms the entire system, including the perimeter and interior devices. The Ready light must be on to arm the
system. If the Ready light is off, ensure all protected doors and windows are secure or bypassed.
To arm the system, enter a valid access code. To disarm, enter a valid access code.
During exit delay, the Armed and Ready indicators turn on and, If the Audible Exit Delay option is enabled, the keypad
beeps once every second during the exit delay (and three times a second during the last 10 seconds) to alert the user to
leave via a delay zone. The Ready light turns off when the Exit Delay ends.
When the exit delay has expired, the system is armed as indicated by the following conditions:
l
the Ready indicator turns off.
l
the Armed indicator stays on.
l
the panel is silent.
Note:
In Away Arming mode, manually bypassed zones are logged and communicated to the central monitoring station.
3.2.2 Stay Arming
Note:
Requires at least one zone defined as Interior Stay/Away or Delay Stay/Away for this function to work.
Stay Arming is intended to arm the perimeter of the premises while permitting movement within. The Ready light must be on
to arm the system. If the Ready light is off, ensure all protected doors and windows are secure or bypassed. To Stay arm the
system, enter a valid user code and stay within the premises (do NOT violate a zone programmed as Delay). The Armed
light turns on once a function key is pressed or an access code is entered. When a user code is used, the keypad beeps if
the Audible Exit Delay option is enabled. The Ready indicator turns off and the Armed indicator turns on when the exit delay
ends.
Note:
In Stay Arming mode, all auto-bypassed stay/away zones are logged and communicated to the central monitoring sta-
tion.
- 14 -