Section 1: Introduction
1.3 Specifications
Zone Configuration
l
128 wireless zones
l
18 zone types and 9 programmable zone attributes
l
4 touchscreen keypads supported (not evaluated by UL/ULC)
l
4 wirefree keypads (not evaluated by UL/ULC)
l
16 wireless sirens
l
8 wireless repeaters
l
32 wireless keys supported
l
8 wireless repeaters supported. Note that more than one wireless repeater shall be installed in a given fire alarm sig-
naling system to provide a redundant RF transmission path.
Access Codes
l
Up to 100 access codes, plus one installer code and one duress code
l
Programmable attributes and partition assignment for each user code
Warning Device Output
l
Integral sounder capable of 85 dB @ 3m
l
2 remote, wireless indoor/outdoor warning devices supported: models PGx901 (indoor), PGx911 (outdoor)
l
Programmable as steady, pulsed, temporal three (as per ISO8201) or temporal four (CO alarm)
l
Warning device sounds alarms in the following priority: Fire, CO, Burglary
Memory
l
128MB RAM
l
4GB eMMC solid-state drive
l
128MB embedded FLASH memory
Power Supply - North America
Transformer:
Primary: 120VAC, 0.35A, 60Hz Class II
Secondary: 12VDC, 1.16A
Standard Battery
l
Model: DSC model 17000178, 7.4V,1.0Ah lithium-Ion, rechargeable (Note: This battery pack shall not be used with
UL/ULC Household Fire Alarm Signaling system)
l
Backup time: 4 hours
l
Recharging time to 85%: 24 hours (UL)
l
Low battery threshold: 7.3V
l
Low battery restore: 7.4V
l
Battery Critical Shutdown: 6.1V
l
Battery lifespan: 3-5 years
Extended Battery
l
Model: DSC model 17000179, 7.4V, 4.5Ah, lithium-Ion, rechargeable
l
backup time: 24 hours
l
Recharging time to 85%: 24 hours (UL)
l
Low battery threshold: 7.3V
l
Low battery restore: 7.4V
- 5 -