VF-500 LINEAR PIEZOELECTRIC AMPLIFIER
Please review the following points for both personal and equipment safety while operating the
linear piezoelectric amplifier.
HIGH ENERGY/VOLTAGE WARNINGS
Exercise caution when using amplifiers. High energy level can be
stored at the output voltage terminals on all amplifiers in normal
operations. In addition, potentially lethal voltages exist in the power
circuit and the output screw terminals. Filter capacitors store
potentially dangerous energy for some time after power is removed.
AC SOURCE GROUNDING WARNING
Ensure that the amplifier’s power supply is connected to a grounded AC outlet with the
recommended AC input connector configured for the available line voltage.
OPERATING AND SERVICES PRECAUTIONS
Operate the amplifier in an environment free of flammable gases or fumes. To ensure that its
safety features are not degraded , do not use substitute parts or make any unauthorized
modifications to the amplifier. Contact DSM for service and repair assistance.
VF-500 SPECIFICATIONS
•
Output Voltage:
-30/+150V or -30/+200V
•
Input Voltage Signal (gain = 20):
-1.50V to +7.50V (for –30/+150V unit)
-1.50V to +10.0V (for –30/+200V unit)
•
Maximum Continuous Current:
500mA, > 5msec
•
Maximum Peak Current:
1000mA, < 5msec
•
Dimensions:
100mm x 240mm x 330mm (4” x 9.5” x 13”)
•
Operating Voltage:
85 ~ 264VAC, 47 ~ 63Hz
•
Amplifier bandwidth:
5kHz
•
Electrical Noise on Output:
4mVrms
•
Short circuit, over-current, and over-temperature protection
•
Output Connector:
SMA
•
Input Connector:
BNC
NOTE: The output voltage is configured at the factory and is not re-configurable in the field.
CAUTION
RISK OF DANGER