background image

* Fire protection / PA system 

Digital Programming Conference System 

5.        Precautions for Operation 

 

5.1 Precautions for Safety Operation 

 

Please  do  not  insert  the  power  supply  plug  of  the  equipment  into  the  power  network  before  connecting 

properly the system circuitry.   

 

It  should  be  ensured  that  the  voltage  supplied  to  the  equipment  be  completely  meeting  the  voltage 

requirements of the equipment, otherwise, there may exist the risk of burning the equipment.   

 

  Danger voltage is inside the equipment, and the voltage is high enough to result in the personnel electric 

shock. Please do not open the housing without authorization to prevent the risk of electric shock.   

 

When  the  power  switch  of  the  equipment  is  at  "OFF"  status,  the  machine  is not  disconnected  completely 

with  the  power  network.  For  your  safety,  please  pull  out  the  power  cord  from  the  socket  when  the 

equipment is not to be used.   

 

Please do not place the equipment at a location too cold or too hot.   

 

Ensure  a  good  ventilation  and  a  good  working  condition  for  the  equipment  to  prevent  heating  in  the 

working hours, otherwise, the machine may be damaged due to too high a temperature.   

 

The master power switch should be turned off at a cloudy day and damp weather or when the equipment is 

not to be used for a long time.   

 

It  is  required  to  pull  out  the  power  plug  to  ensure  that  the  equipment  is  completely  disenaged  from  the 

power  network  when  it  is  to  dis-assemble  or  re-assemble  any  part  of  the  equipment  or  to  disconnect  or 

connect plug of any electric apparatus of equipment or making other connection.   

 

When the equipment has a failure, it is not allowed for the non-professional personnel to open the housing 

to undertake the repair without authorization to prevent accident or aggravating the damaged condition of 

the equipment.   

 

Do not place any chemical subject with corrosivity near the equipment or on the top of equipment.   

5.2 Precautions for After-sales Service 

 

The company will provide free of charge guarantee service (including provision of replacement part free of 

charge)  for  one  year  dating  from  the  day  of  purchase  for  any  quality  problem  in  the  normal  range  of 

application, provided that the installation and application are in conformity to the stipulations given in the 

Operation Manual.   

 

At  any  time  for  the  repair  guarantee,  the  consumer  should  present  the  Card  of  Guarantee  and  the  sales 

invoice as a proof.   

 

The following conditions do not belong to the scope for free of charge service:   

(1) 

Product damage due to mistaken installation, application or handling;   

(2) 

Product damage due to abnormal condition (such as over power voltage or ambient humidity, etc. );   

(3) 

Product damage due to force majeure such as calamity or accident;   

(4) 

The number on product body has been converted, altered or removed;   

(5) 

The product has once been repaired or modified by personnel not authorized by our company; 

 

 

Please keep the Operation Manual and Card of Guarantee carefully.   

 

As to the subjects or precautions not mentioned in the manual, please contact the distributor or visit the web 

page of our company: //www. dsppa. com when necessary.   

 

Please contact the service personnel  of  the company  (or the distributor) if there is any failure phenomena 

during the period of garantee, and the company shall not take the responsibility to repair free of charge if 

the damage is due to dis-assembling by yourself or from the repair by the technical personnel not from the 

company. 

Summary of Contents for CM-60

Page 1: ...CM 60 CM 61 User Manual Welcome your entering DSPPA family music control system For better use of the equipment you are invited to read the manual carefully before operation G u a n g z h o u D S P PA Au d i o C o L td http www DSPPA com CM60 CM60 ...

Page 2: ...p 3 3 2 1 Free Speech Mode 4 3 2 2 First In First Out Mode 4 3 2 3 Limit Speech Mode 4 3 2 4 Three Subsidiary Modes 4 3 2 5 Free Speech Mode Setup 4 3 2 6 First In First Out FIFO Mode Setup 5 3 2 7 Limit Speech Mode Setup 5 4 Microphone Unit CM60 CM61 6 4 1 Functions of Delegate Unit CM61 6 4 2 Functions of Chairman Unit CM60 6 4 3 Appearance of Microphone Unit 6 5 Precautions for Operation 7 5 1 ...

Page 3: ...DIN sockets used for multiple system links Each channel can control 35 sets of microphone The panel is provided with digital display and multiple operation mode indicators The operating state is clear at a glance There are three function setup keys Mode Set and Enter It supports multiple conference modes Free speech mode alternation mode and limit speech mode A Free speech mode All present units c...

Page 4: ...rst Out mode indicator Fifo 5 Limit mode indicator Limit 6 Chairman Only mode indicator C only 7 Auto power off indicator A Off 8 Chairman priority music indicator Music 9 Digital function window two segment digital display 10 System main volume adjustment knob VOL 11 System bass tone adjusting knob LO 12 System treble tone adjusting knob HI 13 Telephone conference switch and telephone volume adju...

Page 5: ...66 3 1 System Connection 3 2 Function Mode Setup Connect the system as per the connection diagram and press the power switch to turn on the power Select the operation mode of the system according to the requirements of conference For control unit setup there are three kinds of principal mode Fully Free mode Free First In First Out mode Fifo and Limit mode Limit Only one of the three modes can be s...

Page 6: ...etup limit Chairman microphone is free from this function limit The priority key on it acts on all the delegate units 3 2 4 Three Subsidiary Modes Chairman Only mode It means all delegate microphones will be turned off when pressing down the priority key on chairman microphone Delegate microphones cannot be turned on again unless turning off the chairman microphone Chairman Common mode All the del...

Page 7: ...ime function After making the last selection press Mode key to save all the operations If the selective mode is Free Speech mode Chairman Only Auto Power off Chairman Priority Music Chime then the indication on the panel is shown as below 3 2 6 First In First Out FIFO Mode Setup Press Mode key until indicator FIFO flashes then press Enter key In such a case only indicator FIFO flashes in three pri...

Page 8: ...seconds after the speech 4 2 Functions of Chairman Unit CM60 In addition to having all the functions of a delegate unit the chairman unit also has the following functions Priority speech function of interrupting speech in the other microphones Providing priority music chime Free from any restrictions in the system and can be placed at any location in the system circuit With Chairman Only mode 4 3 ...

Page 9: ...lowed for the non professional personnel to open the housing to undertake the repair without authorization to prevent accident or aggravating the damaged condition of the equipment Do not place any chemical subject with corrosivity near the equipment or on the top of equipment 5 2 Precautions for After sales Service The company will provide free of charge guarantee service including provision of r...

Page 10: ...tatic power dissipation 8W Max power 65W Output power 36W 18V channel Audio output Impedance 100Ω unbalanced Input sensitivity 100 10mV Freq Response 50 16kHz S N S N 65dB HD 0 5 Weight About 6 5KG Size 484L x 365W x88H mm Color Black Guangzhou DSPPAAudio Co Ltd ...