SAFETY OF USING THE AUTOMATION SYSTEM

·

During automation system operation   both children and adults must keep a safe distance from 
working automation.

·

Only appropriately trained adults can use the automation system.

·

Controlling devices must be out of the reach of children in order to protect the automation system 
against accidental starting.

·

Moving between leaves of the gate is permitted only when it is fully open.

·

Do not hamper the move of automation elements, remove all obstacles hampering the move.

·

Ensure the operation and good visibility of signal lamps and information boards.

·

The manual service of the system is possible only when power supply is disconnected.

·

In case of the breakdown, disconnect the power supply, and next call the service company which will 
perform necessary repairs.

·

Do not repair or maintain the device yourself. Only qualified personnel can perform the service of 
the device.

Non-observance and not-abiding remarks with these symbols can lead to the accident resulting in 

injury of people or material damage. It is necessary to read carefully the following warnings.   The driver 
ensures correct and safe operation only when installed and used according to the given safety rules. DTM 
System is not responsible for accidents resulting from incorrect usage or non-professional installation of 
the devices.

·

Please make sure that the persons installing, maintaining or operating gate automation follow 
these instructions. It is necessary to keep these instructions in such a place that they are easy to find 
when needed.

WARRANTY

DTM System provides operational and ready to use devices and gives 24 months warranty from the 

selling  date  to  the  end  customer. This  time  is  counted  according  to  the  producer  warranty  labels  or  serial 
numbers placed on every product. DTM System obliges itself to repair the device for free if during the warranty 
period there are problems which come because of its fault. Broken device should be supplied on customer’s 
expense  to  the  place  of  purchase  and  enclose  clear  and  brief  description  of  the  breakage.  The  cost  of 
mount/dismount is covered by the user. The warranty does not cover any faults caused by improper usage, user 
self  repairs,  regulations  and  adaptations,  lightning  strikes,  voltages  or  short  circuits  in  the  electrical  grid. 
Appropriate legal acts regulate details of the warranty.

2

Summary of Contents for SWIFT6

Page 1: ...AUTOMATION SYSTEMS DRIVER FOR SWIFT6 DRIVE Assembly manual for the installers SWIFT6 CB ver 1 0 automation systems ...

Page 2: ......

Page 3: ...ards associated with movingofmovablemechanicalelementssuchascrushing hitchingordetachment DTM System company is not responsible for safe and efficient operation of the device in case of applyingcomponentsnotbeing productsofferedbyDTMSystem Useonlyoriginalpartswhileservicing Donotalterorchangetheelementsofthedevice Inform the end user of the manner of the service dealing with breakdown and about th...

Page 4: ...ver ensures correct and safe operation only when installed and used according to the given safety rules DTM System is not responsible for accidents resulting from incorrect usage or non professional installation of thedevices Please make sure that the persons installing maintaining or operating gate automation follow theseinstructions Itisnecessarytokeeptheseinstructionsinsuchaplacethattheyareeasy...

Page 5: ...ressureedgesanditalsohasencodersystemefficientlydetectingtheoverloadingcausedby the unintentional resistances in the move of the gate The driver detects and also uses the operation of internal magnetic limit switches of the motor Moreover the driver enables the adjustment of the power and has a functionofslowingdownduringstartandstop Thedriverhasaradioreceiverconnector 3 Technicaldata Basic parame...

Page 6: ...eters to the current installation inparticularitisnecessaryto 4 alwayssetthepowerofmotors 4 alwayssetopeningandclosingtimesandthelimitofoverloadingsafetybarrier Scrupulously follow designed connections If uncertain do not try but read relevant detailed technical cardsofinstalleddevices Incorrectconnectionscancauseseriousdamageinthedriverandotherdevices 1 Connector powering the transformer 2 Transf...

Page 7: ...ust be connected to clamps IfwhileprogrammingthegateopensinthewrongwayitisnecessarytochangewiresonclampsCH andAP 4 3 3 ClampsforconnectinglimitswitchFCA C FCC 18 20 fig 2 Clamps are used to connect built in limit switch Magnets which cooperate with the switch have different polarization Before the programming make manual move with gate and make sure that the switch correctlyinterpretsoutermostposi...

Page 8: ...g opening fast flickering closing 2 flashes countdown of closing time see fig 2 Output load is 100 m A what is sufficient for controllingelectromagnetictransmitters24VAC 4 3 10 ClampsforconnectingphotocellsFT1 11 fig 2 FOTO1 input FT1 is dedicated to the photocell of the gate having the function of stopping the gate movewhileclosing CorrectlyconfiguredJOLLYinput JOL canperformthefunctionofstopping...

Page 9: ...8 29 30 31 F0 3A 24V motor Rx Tx control board supply 24VAC orange Signal lamp 230VAC Lamp 230VAC OPEN PROG STOP P P CLOSE STEP BY STEP STOP JOLLY PHOTO1 COM photocells with photo test power supply COM MOTOR blue PE ENCODER Transformer power output Control board supply 12VAC white Limit switch supply 24V yellow COM brown FC 1 green FC 2 white CAPACITOR FCC Ap Ch P P Stop Jolly FT1 FCA Supply 230V ...

Page 10: ...themiddleoftheway 1 fig 3 4 press PROG STOP button and hold it pressed for about 3 seconds until L1 diode does not light constantly 2 fig 3 Driverisintheprogrammingmode 4 Press P P button The gate will start moving in direction toward closing 3 fig 3 If the gate moves on the direction towards opening it is necessary to change the direction of engine operation and limit switch operation seept 4 3 2...

Page 11: ...Ifthisopeningrequiresmodification actinthefollowingwayusingJOLLYinput clamp10fig 2 4 With the gate closed enter the programming mode by holding the PROG STOP button up to the moment untilaL1diodeturnson 4 PressPEDbutton thegatestartsopening 4 Next press PED button at the moment when the gate reaches the demanding position of opening for pedestrians 4 Thegatestops nextitstartsclosing Thedrivesgoeso...

Page 12: ...f slowing down standard slowing down increased slowingdownforheavierautomation Procedureofslowingdowntypechange 4 disconnectthedriverpowersupply 4 connectthepowersupplyagainholdingpressedSTOP PROGbuttons 4 L1diodeturnsonafter3seconds 4 still holdingSTOP PROG buttons set DIP SWITCH 9 from theOFF position to theON if DIP SWITCH is set ON switchitontheOFFpositionandnextON 4 L1diodestartspulsing 4 fas...

Page 13: ...CAUTION SETTINGS CHANGE REQUIRE DRIVE RESTART BY SWITCHING MOTOR SUPPLY OFF FORAMOMENTORBYSHORTCIRCUITOFRESETPINS 15 fig 1 open stop close open close While opening after pressing P P button the gate stops for a few seconds later it closes While closing after pressing P P button the gate stops for a few seconds later it opens always opens While closing pressing P P button stops the gate for a few s...

Page 14: ...n themotorshouldmakeamovetowardsclosing 4 Sprawdziæ funkcjê ZAMYKANIE u ywaj c przycisku pilota lub przycisku rêcznego PC Przy ca kowicie lub czêœciowo otwartej bramie podaæ impuls z przycisku ZAMYKANIE si ownik powinien wykonaæ ruch w kierunkuzamykania 4 Check STOP function by using manual button During motor move in direction towards closing or opening giveimpulsefromSTOPbutton thedriveshouldsto...

Page 15: ...tronic devices cannot be removed with everyday waste The correct recycling of devices gives the possibility of keeping natural resources of the Earth for a longer time and prevents the degradation of natural environment ...

Page 16: ...DTM System spó ka z ograniczon odpowiedzialnoœci spó ka komandytowa ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl desing and production of electronic devices gate automation ...

Reviews: