10
b)
Pos Close, Gate will close hard on end stopper and release automatically in the
gearbox. (No movement will be visible on the gate)
•
From desired selection, scroll down to MENU BACK and press ENT button three times.
c) LOAD=
•
Press ENT button and an arrow will appear next to LOAD=.
•
Select with UP or Down buttons the required % from Min. 20% to Max. 100%.
•
Press ENT button on desired %.
d) COLL=
•
Press ENT and an arrow will appear next to COLL=.
•
Select with UP or Down buttons the required % from Min. 15% to Max. 100%.
•
Press ENT button on desired %.
e) SBEAM NORM, SBEAM TEST
•
Select either, No IR Beam, IRClose (normal w/o test), IR Close+T (with test before
closing), IR CL+OP (normal c opening beams) or IR CL+OP+T (c opening
beams with test)
•
Scroll down to MENU BACK when selection was made.
•
Press ENT button twice to exit.
2 - HI ACCESS or DOMESTIC
(Generally select HI ACCESS)
•
Select Hi Access or Domestic by pressing the ENT button.
•
Press ENT button to exit.
•
Note
: If High Access is selected then:- (PIRAC, CONDO & Auto close will be ON)
If Domestic is selected then: - (PIRAC, CONDO & Auto close will be OFF)
On both of the above - PIRAC, CONDO & Auto close can still be change as required.
3 - 100-400Kg or 400-700Kg or 700-1000Kg
(Force requirement)
(Generally select, 400-700KG)
•
Select the required Kg gate weight by pressing the ENT button.
•
Press ENT button to exit.
-----------------------------------------------------------------------------------------------------
From TEST MODE, scroll down to
REMOTES
and press ENT. Screen will display:-
LRN GATE, LRN PED, LRN RELAY, LRN MASTER, DELETE and DELETE ALL.
Select required function and press ENT button.
1
- Lrn Gate
(Full open trigger)
•
Once you have pressed the ENT button.
•
Enter key P1 will appear with some blocks below the time out period to press and
release your transmitter button.
•
If the remote is successfully accepted, P2 will appear.
•
Press and release the transmitter button again.
•
The display will indicate which location the transmitter was saved in.
•
Press MENU with ENT button back to exit.
•
Should the display indicate Learn failed, Press on MENU BACK the ENT button and start
again.
2 – Lrn Ped
(Pedestrian trigger)
•
Follow the same steps as for LRN GATE.
3 – Lrn Relay
(Will trigger item connected to relay output on PCB)
•
Follow the same steps as for LRN GATE.