5
WARNING:
Electronic equipment dropped from desk height onto a concrete floor may
experience as much as 10,000 Gs. Under these conditions, damage to the
exterior and/or interior of the unit is likely.
Shock Rating
All TDAS systems are rated for and tested to greater than 120 Gs, 12 mS duration, in
all axes. TDAS G5 equipment can be mounted directly on a vehicle, sled or other
dynamic testing device.
Power Connections and Considerations
A good power source is of paramount importance. TDAS G5 systems should be
powered from a fully charged 12-volt battery or a high-quality power supply with a
nominal output voltage of 13.8 volts (10-14 volt range).
G5-DB Interface Connectors & Cables
The end view of the G5-DB is shown below. Connector pinouts are given in
Appendix A.
The G5-DB to Dummy Exit cable is installed on the External Function Connector.
External functions include Ethernet communications, trigger, external power and
External
Function
Connector
1 2 3 4 5
Local
Function
Connector
G5 Module
Connectors