TDAS G5 DAS 

User’s Manual

 

October 2019 

 
 

 
 

support.dtsweb.com

 

8

 

11000-00010-MAN (Rev. 5)

 

Basic Care and Handling 

TDAS G5 DAS units are precision devices designed to operate reliably in dynamic testing 

environments.    Though  resistant  to  many  environmental  conditions,  care  should  be 
taken not to subject the unit to harsh chemicals, submerge it in water, or drop it onto 

any hard surface. 

WARNING: 

Electronic  equipment  dropped  from  desk  height  onto  a  solid 
floor  may  experience  as  much  as  10,000 g.    Under  these 
conditions, damage to the exterior and/or interior of the unit is 
likely. 

Should a TDAS G5 DAS be removed from its docking station, we recommend that you 

always cover the 216-position interface connector with the rubber cap provided with the 

unit.    If  you  feel  the  interface  connector  on  your  TDAS  G5  DAS  unit  has  become 
contaminated, please contact DTS support before attempting any cleaning procedure.  

When not in use or if shipping is required, we suggest that you always place the unit in 
the padded carrying case originally provided with your system. 

WARNING: 

The  gold-plated,  216-position  interface  connector  on  the 
TDAS G5 DAS should be treated with great care.  It is through 
this interface that all signals enter and exit the DAS.  Any debris, 
solvents,  or  oil  (even  from  fingers),  can  compromise  the 
integrity of the connections/signals. 

The TDAS G5 DAS is supplied with calibration data from the factory.  DTS recommends 
annual recalibration to ensure that the unit is performing within factory specifications.  

It is not user-serviceable and should be returned to the factory for service or repair. 

Shock Rating 

TDAS G5 DAS units are designed to function routinely in a 500 g environment such as 

that experienced in severe in-dummy applications.  All vehicle-/sled-mounted systems 
are rated for and fully tested to 100 g, 12 msec duration, in all axes.  TDAS G5 equip-

ment can be mounted directly on a vehicle, sled or other dynamic testing device. 

 

 

Summary of Contents for TDAS G5

Page 1: ...11000 00010 MAN Rev 5 Diversified Technical Systems Inc All Rights Reserved TDAS G5 Data Acquisition System User s Manual October 2019...

Page 2: ...Considerations 9 Power Considerations 10 Power Consumption and Management 10 Power Requirements and Memory Retention 10 External Power Provisions 10 Communication Features 11 Communication Method 11 L...

Page 3: ...ail or on site visits The best way to contact a DTS support engineer is to submit a request through the DTS Help Center web portal support dtsweb com You must be registered support dtsweb com registra...

Page 4: ...e 216 position interface connector LED indicators for communication calibration power arm status and event status Back up battery input for safe operation even with loss of primary power Please see th...

Page 5: ...checks are performed under software control settings are calculated by the software and the applied shunt signal is automatically scaled to an appropriate percentage of the requested range See the TD...

Page 6: ...gh bandwidth EID Support Each TDAS G5 DAS measurement channel supports communication with silicon serial number devices manufactured by Dallas Semiconductor Maxim Integrated Products When you connect...

Page 7: ...treated with great care as any debris solvents or oil even from fingers can compromise the integrity of the connections signals Proper orientation can be determined by locating the board references J1...

Page 8: ...tempting any cleaning procedure When not in use or if shipping is required we suggest that you always place the unit in the padded carrying case originally provided with your system WARNING The gold p...

Page 9: ...as possible will minimize self heating It is unlikely that the units will be damaged by excessive heat because power is internally limited by self resetting thermal fuses the units will simply shut do...

Page 10: ...oring data After the data collection routine is complete the TDAS G5 DAS de energizes several circuits to minimize power consumption It takes a maximum of 125 seconds for 70 seconds of data at 10k sam...

Page 11: ...n status with the docking station and DAS CAL Provides calibration status PWR Provides status on power to the DAS ARM Provides arm start record and event status STAT Provides general status TDAS G5 DA...

Page 12: ...cle applications as needed In dummy Docking Station Configuration The iDummy docking station allows for easy installation and removal of the TDAS G5 DAS into virtually any crash dummy type Signals ent...

Page 13: ...for on board testing applications Power commu nication and event signals are easily accessible via the control panel A variety of larger sensor connectors such as LEMO 1B or equivalent can be easily...

Page 14: ...TDAS G5 DAS User s Manual October 2019 support dtsweb com 14 11000 00010 MAN Rev 5 Appendix A TDAS G5 DAS 216 position Interface Connector...

Page 15: ...AN Rev 5 Appendix B Mechanical Specifications Weight 200 grams TDAS G5 DAS TDAS G5 DAS standard high bandwidth 3 374 inches 85 7 mm 2 677 inches 68 mm 0 472 inches 12 mm 0 158 inches diam 4 0 mm diam...

Page 16: ...DAS Firmware Loader provided with the TDAS Control software establish communication with the DAS unit To do this change the fields to the appropriate hardware G5 serial number of the DAS unit and comm...

Page 17: ...Command fpget name read parameter fpset Set parameter set parameter into flash memory Command fpset name value set parameter Confirm or change the TDAS S N field Type the command on the Input Command...

Page 18: ...d or any text editor 4 Find the line titled Rack Inventory and change the IP address associated with the serial number for the TDAS G5 DAS to the new address Note Change only the IP address and not th...

Page 19: ...om the factory with the default IP address shown on the packing list for the equipment If the packing list is not available and you need information on the specifics of your equipment please submit a...

Page 20: ...d TDAS G5 DAS Interface Connector section Updated Appendix D DTS Support boilerplate and support link in footer Removed HQ address Rev 5 04 Dec 2013 EK Updated DTS Support Input Range Hardware Filters...

Reviews: