9
ZKL 3000 RC
6. CONTINUATION TESTING THE ZKL 3000 RC
The override key switches the ZKL 3000 RC
ON
or
OFF
without using either an RS 3000 or
MTinfo 3000. Use of the override key will overrule commands sent by both the RS 3000 and
MTinfo 3000 as the key switch always takes priority. Usually, the key switch would only be used
as a last resort.
Attention! The
OPERATIONAL
position has two settings.
OPERATIONAL
-
ON
: When switched from the
ON
to
OPERATIONAL
(one turn to the left),
the ZKL 3000 RC remains activated creating a short circuit. However, it will now be possible to
remotely operate the ZKL 3000 RC using either an RS 3000 or MTinfo 3000.
OPERATIONAL
-
OFF
: When switched from
OFF
to
OPERATIONAL
(one turn to the right), the ZKL
3000 RC remains deactivated. Again, it will now be possible to remotely operate the ZKL 3000 RC
using either an RS 3000 or MTinfo 3000.
c. Function test for installation
• Ensure that the contact points and the Test-Tool are clean
• With the Test-Tool present (as shown below), press the contact points together and switch
the ZKL 3000 RC ‘ON’ using the override key
• The green LED should start flashing (twice per second), indicating that a short circuit has
been detected. Check this status for at least five seconds
• If all is OK and the green LED continues to flash, switch the ZKL 3000 RC ‘OFF’ using the
override key. The LED should stop flashing. Again, check this for at least five seconds
• If the LED remains off, remove the Test-Tool. The ZKL 3000 RC is ready to be deployed
ATTENTION: If the ZKL 3000 RC does not pass the functional test before installation,
do NOT use the unit. Apply a label to the ZKL 3000 RC, quarantine it and return to your
depot/warehouse to be returned to Dual Inventive for repair.
>
>