13
ZKL 3000 RC
7. CONTINUATION INSTALLING THE ZKL 3000 RC
c. LED Indications
You may find the following situations on the ZKL 3000 RC:
• Green led is flashing
status safe
• Cause: ZKL 3000 RC has been switched on and is measuring a short circuit
• Green and red LED are off
no detection
• Possible causes:
- ZKL 3000 RC has not been switched on
- ZKL 3000 RC does not have any power
- ZKL 3000 RC is defective. Remove the ZKL 3000 RC from the track, label, quarantine
and send it to Dual Inventive for repairs
- ZKL 3000 RC does not have a good connection with the rails
Use MTinfo 3000 (https://mtinfo.dualinventive.com), the Dual Inventive app or an RS 3000
to see the status. More information can be found in the chapter “Troubleshooting”
• If the red LED is permanently illuminated
• Cause: power supply is below desired level
• Solution: Replace the battery as soon as possible
d. Replacing external battery
When the ZKL 3000 RC indicates that the power supply is low, it must be replaced.
• Disconnect the power cable from the external battery
• Insert a fully charged, external battery and connect it to the power supply cable
• The backup battery will start charging automatically
• Report to the relevant person within your organisation that the external battery has been
replaced. This is because MTinfo 3000 will report that the battery was disconnected next time a
project is released
>
>