17
ZKL 3000 RC
9. TRANSPORT & STORAGE
a. Transport
a. Transport
• Always use the transport case to transport the ZKL 3000 RC when possible. The ZKL 3000 RC
transport cases are equipped with wheels for use on solid ground and are horizontally stackable
• Transport the RS 3000 separately in the designated transport case
• If you transport the ZKL 3000 RC without a case, carry it horizontally next to the body and
use the handle ensuring the contact points of the ZKL 3000 RC point forward
• Make sure the locking mechanism is latched shut
• During transport, ensure your own safety at all times
b. Storage
Careful maintenance and adequate storage of the ZKL 3000 RC prolongs its life span.
• Clean the ZKL 3000 RC every four months with a cloth and/or brush
• When frequently used, you should regularly clean the sprung contact legs and the contact
points. Debris can cause parts to wear faster
• Clean the contact points with a wire brush
• Use the transport case to store the ZKL 3000 RC and store it in a dry, well ventilated area.
This also applies to the RS 3000
• Do not store a wet ZKL 3000 RC in a closed case for a long period of time. This will cause mould
10. MAINTENANCE & SERVICE
a. Maintenance
It is possible that due to rust, the ZKL 3000 RC’s ability to create and detect a short circuit is
decreased. This will be noticeable if you have to resend the ‘ON’ command multiple times, even
though the green LED is flashing. In this case, the contact points are probably worn, and they
should be replaced. These can be supplied by Dual Inventive. The ZKL 3000 RC does not need to
be recalibrated during this maintenance.
To replace the contact points, use a torx wrench T25 to loosen the bolts. After you have
completely removed the bolts, you can install the new contact points by reusing these.
When installing contact points, please tighten to a torque of 6.1 Nm.
>
>
index
>