8
ZKL 3000 RC
6. TESTING THE ZKL 3000 RC
a. Preparations
Before you start, check whether the ZKL3000 RC system’s calibration is still in date.
You can find the “Next calibration date” sticker on the measuring unit.
Discharge and charge the batteries at least twice before the first use to ensure full power capacity.
See section “Charging the batteries”.
Before
installation, the user should check the ZKL 3000 RC for defects and perform a function test.
Testing the ZKL 3000 RC should always be done in a position of safety.
• Before testing, clean the contact points with a wire brush to ensure the best possible connection
• Before use, place two fully charged batteries into the ZKL 3000 RC
• Open the battery cover with the compartment key
•
ALWAYS
place the power cable on the notched side of the battery compartment
• Insert the batteries and pull the rubber fastener over the battery ends to lock them in position
• Close the battery cover and lock it with the compartment key
• Wait at least 10 seconds after installing the batteries to allow the ZKL 3000 RC to switch on
• Using the override key switch, switch the ZKL 3000 RC on
b. The override key switch
The override key switch has three positions:
Key up (fully clockwise)
=
ON
The ZKL 3000 RC has now been activated in an overruled
manner and produces a short circuit. The unit cannot be
operated remotely.
Key horizontal
=
OPERATIONAL
The ZKL 3000 RC is now operational and can be operated
remotely by either the RS 3000 or MTinfo 3000.
Key down (fully counter-clockwise)
=
OFF
The ZKL 3000 RC has now been activated in an overruled
manner and will not produce a short circuit. The unit
cannot be operated remotely.
>
>
index
>