Inhomogeneous strings
–
Direct pool heating system (wintering draining)
Where Tichelmann hydraulic loop balancing is not feasible or the panel strings are not homogeneous, different
number of panels per string and/or panels laid in different directions (portrait / landscape), the installation of
balancing valves is recommended. The sizing of the balancing valves depends on the number of panels per string and
the recommended nominal flow rate, see chapter
Erreur ! Source du renvoi introuvable.
. With PVC pressure pipes, it
is necessary to install a stop valve and a float flowmeter vertically. The flow adjustment depends on the number of
panels per string, see
Erreur ! Source du renvoi introuvable.
.
Figure 34 : Hydraulic balancing
–