background image

FPBB050A3B

FPBB075A3B

FPBB100A4B

FPBB125A5B

GAS

NATURAL (LP with conversion kit) 

INPUT RATE (BTU per Hour)

50,000

75,000

100,000

125,000

HEATING CAPACITY (BTU per Hour)

40,000

61,000

81,000

101,000

AFUE (ISOLATED COMB. SYSTEM)

80%

TEMPERATURE RISE

30 - 60 F

40 - 70 F

VOLTS / PHASE / HERTZ

115 /1/ 60

STATIC PRESSURE (CERTIFIED MAX)

0.50" W.C.

BLOWER MOTOR HORSEPOWER

1/3

1/2

3/4 

BLOWER WHEEL (DIA. X WIDTH)

10 x 6

12 x 9

12 x 12

NUMBER OF HEAT EXCHANGERS

2

3

4

5

LIMIT CONTROL, SNAP DISK STYLE

150 F

170 F 

170 F

150 F

IGNITION CONTROL

DIRECT SPARK

TRANSFORMER

40 VA, 115VAC PRIMARY, 24VAC SECONDARY, FOOT-MOUNTED

INTEGRATED CONTROL SYSTEM

INTEGRATED FURNACE CONTROL

SHIPPING DIMENSIONS

54 X 26 X 25 3/4

54 X 29 X 25 3/4

54 X 33 X 25 3/4

SHIPPING WEIGHT

144

153

175

197

MAXIMUM DESIGN OUTLET TEMP.

170 F

AUXILIARY LIMIT

130 F 

140 F

UNIT SPECIFICATIONS 

HORIZONTAL 80

TM

D u c a n e   G a s   F u r n a c e

FPBB075A4B

FPBB100A5B

GAS

NATURAL

INPUT RATE (BTU per Hour)

75,000

100,000

HEATING CAPACITY (BTU per Hour)

61,000

81,000

AFUE (ISOLATED COMB. SYSTEM)

80%

TEMPERATURE RISE

30 - 60 F

VOLTS/PHASE/HERTZ

115/1/60

STATIC PRESSURE (CERTIFIED MAX)

0.50 "W.C. 

BLOWER MOTOR HORSEPOWER

1/2 

3/4

BLOWER WHEEL (DIA. X WIDTH)

10 X 6

12 X 9

NUMBER OF HEAT EXCHANGERS

3

4

LIMIT CONTROL, SNAP DISK STYLE

170 F 

160 F 

IGNITION CONTROL

DIRECT SPARK

TRANSFORMER           

40 VA. 115VAC PRIMARY, 24VAC SECONDARY, FOOT-MOUNTED

INTEGRATED CONTROL SYSTEM

INTEGRATED FURNACE CONTROL

SHIPPING DIMENSIONS

54 1/2 X 26 X 25 3/4

54 1/2 X 29 X 25 3/4

SHIPPING WEIGHT

157

183

MAXIMUM DESIGN OUTLET TEMP.

170 F

AUXILIARY LIMIT

130 F

140 F

UNIT SPECIFICATIONS HIGH AIR FLOW MODELS

Summary of Contents for Horizontal 80

Page 1: ... year limited warranty on heat exchanger 5 year limited warranty on covered components see warranty certificate for details HEAT EXCHANGER ASSEMBLY Crimp Tite crimped aluminized steel heat exchanger for longer life and safe operation VENTING Category I venting 4 vent vertical or horizontal with approved power venter Inducer orientation allows for 360 vent connection CONTROLS Integrated furnace con...

Page 2: ... 54 X 33 X 25 3 4 SHIPPING WEIGHT 144 153 175 197 MAXIMUM DESIGN OUTLET TEMP 170 F AUXILIARY LIMIT 130 F 140 F UNIT SPECIFICATIONS HORIZONTAL 80TM D u c a n e G a s F u r n a c e FPBB075A4B FPBB100A5B GAS NATURAL INPUT RATE BTU per Hour 75 000 100 000 HEATING CAPACITY BTU per Hour 61 000 81 000 AFUE ISOLATED COMB SYSTEM 80 TEMPERATURE RISE 30 60 F VOLTS PHASE HERTZ 115 1 60 STATIC PRESSURE CERTIFI...

Page 3: ...1285 1165 1045 B100A4B LOW 1260 1235 1205 1175 1140 1105 1065 1025 985 940 12 X 9 WHEEL MED 1470 1465 1465 1455 1435 1410 1375 1335 1295 1240 1 2 HP MOTOR HIGH 1845 1825 1795 1755 1715 1665 1610 1550 1485 1410 B100A5B LOW 1380 1365 1340 1305 1265 1215 1160 1090 1015 925 12 X 9 WHEEL MED 1795 1780 1755 1720 1670 1610 1540 1455 1360 1255 3 4 HP MOTOR HIGH 2385 2330 2265 2195 2105 2015 1910 1795 1670...

Page 4: ...1 7 121 FPBB100A4B 50 17 23 1 8 15 1 8 21 3 8 4 23 FLUSH 9 9 141 FPBB100A5B 50 17 23 1 8 15 1 8 21 3 8 4 23 1 13 1 141 FPBB125A5B 50 20 1 2 23 1 8 18 5 8 21 3 8 4 26 1 2 FLUSH 11 7 161 NOTE Dimensions are in inches GENERAL LAYOUT B D H G F A E C DUE TO OUR POLICY OF CONTINUOUS IMPROVEMENT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Printed on recycled paper 09 02 30K www ducanehvac com For mor...