32
ENGLISH
L2003212 Installation guide for DucoBox Energy Comfort (Plus) (Revision A | 18.10.2022)
09.E
Menu structure
The chart below contains all the menus in the DucoBox Energy Comfort (Plus)� Menus with a padlock ( ) are only visible to the
installer after entering the installer’s code
9876
�
The chart below may differ depending on the DucoBox Energy Comfort (Plus) software version�
SETTINGS
COMFORT TEMPERATURE
The DucoBox Energy Comfort (Plus) will seek to maintain the temperature
in the house at the set value� The DucoBox Energy Comfort (Plus) also
features a smart algorithm which will automatically adjust the comfort
temperature depending on the outdoor temperature� This will maintain
the temperature in the house at the most comfortable level possible for
the resident�
With zoned control, a comfort temperature can be set for each zone�
UNIT CONTROL
Option to change the ventilation position via the display menu
PROGRAMME
A set timetable can be programmed into the ventilation unit� You can use
this to increase or decrease the ventilation in the house at fixed times�
BYPASS
The DucoBox Energy Comfort (Plus) features a fully automatic bypass� This
enables the house to cool down to the desired comfort temperature during
summer nights� It is also possible to deactivate the bypass temporarily or
completely to increase user comfort�
DATE & TIME
The DucoBox Energy Comfort (Plus) has an inbuilt clock which is required
for the time-dependent controls�
LANGUAGE
The menu language can be changed to match the user’s language� The
following languages are available: Dutch, English (standard), French and
German�
LAN SETTINGS
Platform where LAN settings can be defined� Only active when a
Communication Print WIFI is connected, AND there is a positive response
to the IP address query�
MODBUS
Platform where ModBus settings can be defined� Only active when a
Communication Print WIFI is connected, AND there is a positive response
to the ModBus address query�
CONFIG
Other settings�
FROST PROTECTION
Status of frost protection:
STAND-BY
or
ACTIVE
� See also page 31� Other
settings such as
HEATER
AUTO
or
OFF
HEATER
EXT
(pre-heater)
ABSENT
or
PRESENT
NIGHTBOOST
Activate or deactivate and set parameters of the nightboost function�
BUILDING TYPE*
Selection of the parameter
HOUSE
(landed) or
FLAT
(non-landed)�
INFO
TEMPERATURE SENSORS
(for information)
The DucoBox Energy Comfort (Plus) features 4 temperature sensors which
measure the temperature at each duct connection� The values of these
temperature sensors are indicative�
PRESSURE SENSORS
(for information)
The pressure measured in the unit relative to the atmosphere� These
values give an indication about the performance of the system calibration�
BOX SENSORS
(for information)
Measured values for Humidity Boxsensor�
ERROR LIST
Overview of error messages and/or warnings�
DUCO SERIAL NUMBER
(for information)
Serial number of the DucoBox
SOFTWARE VERSION
(for information)
In any communication with DUCO, you may be asked to state the software
version of your DucoBox Energy Comfort (Plus)� Please keep this number
to hand for any communication�
SOFTWARE UPLOAD
All components in the network can also receive a software update via the
DucoBox� The 'Software update' selection field can be used to read out the
percentage status of the update of these components�
SERVICE CODE
This code will enable the DUCO service team to read out the composition
of your ventilation system and its paired components�
UNIT INFO
(for information)
In any communication with DUCO, you may be asked to provide unit details
such as correct name, type, country setting�
FILTER
FILTER STATUS
Remaining filter service life�
REPLACE FILTERS
Step-by-step instructions for replacing filters�
FILTER CLEANING
Step-by-step instructions to clean the filters�
INSTALLATION
WIZARD
Run this wizard to pair components with the system�
RESET NETWORK
This removes all paired control components from the network�
FACTORY RESET
Resets the entire system (= DucoBox Energy Comfort (Plus) + paired
components) to factory settings� The calibration will be lost�
CALIBRATION
WIZARD
Run this wizard to calibrate air flow rates correctly�
VERIFY HIGH LEVEL
Sets the system temporarily to high level to enable calibrated air flow
rates to be verified� Active only if adjustment has been carried out�
CALIB BY CODE
To copy the adjustment of an existing system, a code can be requested or
read in�
ADVANCED
/
CLOSE ADVANCED
Activate / deactivate advanced mode to show / hide functions with a padlock ( )�
* Only if at the first start-up, when choosing the country, “the Netherlands” was