23
ENGLISH
L2000012 Installation guide for DucoBox Eco (Revision E.1 | 13.05.2020)
10
Display menu
The DucoBox Eco features a graphic display which enables all the necessary parameters of the unit to be easily adjusted� Settings
and calibration can also be carried out using the free-of-charge Duco Ventilation App�
10.A
Display overview and operation
The display on the DucoBox Eco has 3 buttons: up ( ), down ( ) and
enter ( )� The arrow keys can be used to scroll through the menu� A menu can
be exited by navigating to ‘
Back
’ or by short-pressing Up ( ) and Down ( )
together�
If the display has not been used in the normal operating mode, it will be deac-
tivated after 1 minute� Press any button at random on the display in order to
reactivate it� Press any button at random again to retrieve the menu�
up
( )
enter
( )
down
( )
Main screen
The display will light up continuously when the DucoBox Eco starts up until calibration has been completed�
The following main screen will be visible after that:
Time
Parameters for
Domestic hot water
Parameters for
Central heating
Measured temperature
Setpoint temperature (= the DucoBox Eco
target temperature)
Frost protection is active�
Menu is in advanced mode�
There is a fault / message.
Electric heater active
(if applicable)
Gas boiler active
(if applicable)
Heat pump active
Thermostat / Aquastat active
Manual mode active
(Boost or Off)