Short Seam Automat 2211-5 Working Instructions
- D 92 -
Beisler Automated Sewing Equipment
D.3
Programming
D.3.10 Level 3 special parameters / Functions
Level 3 submenus
%<;D
238
+
F1 Back to start level
F2 Switch photocell for beginning of seam on or off
F3 Switch photocell for end of seam on or off
F4 Switch folder on or off
F8 Request next level (level 4)
Switching photocell for beginning of seam on or
off:
If the photocell that scans the start position of the seam
is switched off, the machine control requires a fixed inser-
tion distance for machine operation. Therefore, switching
off the photocell results in a switch-over to a fixed inser-
tion length (see Fig. 4). This function is directly related to
the photocell correction functions of the service menu.
<
•
Press
key.
The alternating request of this function switches between
two modes:
Photocell for beginning of seam and fixed insertion di-
stance.
Switching photocell for end of seam on or off:
If the photocell that scans the end position of the seam
is switched off, the machine control requires a fixed point
for the end of the seam to ensure correct machine ope-
ration. Therefore, switching off the photocell results in a
switch-over to a fixed end of seam point. This function is
directly related to the photocell correction functions of the
service menu.
;
•
Press
key.
The alternating request of this function switches between
two modes:
Photocell for end of seam and fixed end of seam point or
fixed seam length.
Switching folder on or off:
The folder puts the pocket edge onto the pocket bag. If
this function is disabled, the pocket edge must be put onto
the pocket bag manually.
D
•
Press
key.