8.8.3
Machine faults/errors
Error code
Description
Possible cause
Remedy
1051
Sewing motor timeout
- Cable to sewing-motor
- Reference switch is
defective
- Sewing motor is defective
- Mechanics are sluggish
- Check the cable
Check the reference switch
- Check
the sewing motor
- Check the mechanics
1055
Sewing motor
overload
- The sewing motor is
blocked or sluggish
- Sewing motor is defective
- Control unit defective
Fix the blockage or sluggishness
Check the sewing motor
Check the control unit
1342
–
1343
Sewing motor error
Internal error
- Switch machine off and on again
- Software update
- Inform DA Service
2101
Step motor, X-axis,
Timeout Referencing
- Cable to reference switch
is defective
- Reference switch is
defective
- Step motor is defective
- Mechanics are sluggish
- Check the cable
- Check the reference switch
- Check the step motor
- Check the mechanics
2103
Step loss-Test:
Step loss X-axis
- Stitch length within the
contour in the X direction
too big
- Reduce the speed
- Reduce the scale of the contour
in the X direction
- Reduce the stitch length within
the contour in the X direction.
2165
–
2167
Step motor data
X-axis
Internal error
- Switch the sewing machine off
and on again
- Software update
- Inform DA Service
2201
Step motor, Y-axis,
Timeout Referencing
- Cable to reference switch
is defective
- Reference switch is
defective
- Step motor is defective
- Mechanics are sluggish
- Check the cable
- Check the reference switch
- Check the step motor
- Check the mechanics
2203
Step loss-Test:
Step loss Y-axis
- Stitch length within the
contour in the Y direction
too big
- Reduce the speed
- Reduce the scale of the contour
in the Y direction
- Reduce the stitch length within
the contour in the Y direction.
2265
-
2267
Step motor data
X-axis
Internal error
- Switch the sewing machine off
and on again
- Software update
- Inform DA Service
2911
2914
Step motor error
Internal error
- Switch machine off and on again
- Software update
- Inform DA Service
3100
Machine control
voltage
Short-term mains voltage
drop
Check the mains voltage
3101
Machine power
voltage
Short-term mains voltage
drop
Check the mains voltage
1