25. Error messages
Error
Info/Description
Remedy
1051
Sewing motor timeout
· Cable to the sewing motor
reference switch faulty
· Reference switch defective
· Replace the cable
· Replace the reference switch
1052
Sewing motor excess current
· Cable of sewing motor faulty
· Sewing motor defective
· Control defective
· Replace the sewing motor cable
· Replace the sewing motor
· Replace the control
1053
Too high mains voltage
Check mains voltage
1055
Sewing motor overcharge
· Sewing motor blocked/moves
too heavy
· Sewing motor defective
· Control defective
· Eliminate the blocking/rough
running
· Replace the sewing motor
· Replace the control
1056
Sewing motor excess
temperature
· Sewing motor moves too
heavy
· Sewing motor defective
· Control defective
· Eliminate the rough running
· Replace the sewing motor
· Replace the control
1058
Sewing motor speed
Sewing motor defective
· Replace the sewing motor
1062
Sewing motor IDMA
Autoincrement
Malfunction
Switch the machine off and on again
1302
Sewing motor: current supply
fault
Encoder cable not connected /
defective
Encoder defective
· Eliminate the blocking
· Check /
Replace the encoder cable
· Replace the sewing motor
1342
-
1344
Sewing motor fault
Internal fault
· Switch the machine off
and on
again
· Software update
· Inform DA-Service
2101
Step motor X-axis timeout
reference
· Cable to the reference switch
faulty
· Reference switch defective
· Replace the cable
· Replace the reference switch
2152
Step motor X-axis excess
current
· Replace step motor X-axis
· Replace the control
2153
Step motor X-axis excess
voltage
Too high mains voltage
Check the mains voltage
64