Error
Info/Description
Remedy
2301
· Step motor Z-axis
timeout reference
· Cable to the reference switch
faulty
·Reference switch defective
· Replace the cable
· Replace the reference switch
2302
· Step motor Z-axis
Current supply fault
· Step motor Z-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Eliminate the blocking
· Check/Replace the encoder cable
· Replace step motor Z-axis
2352
· Step motor Z-axis
excess current
· Step motor Z-axis defective
· Control defective
· Replace step motor Z-axis
· Replace the control
2353
· Step motor Z-axis
excess voltage
· Too high mains voltage
· Check the mains voltage
2355
· Step motor Z-axis
overcharge
· Step motor Z-axis
blocked/moves too heavy
· Step motor Z-axis defective
· Control defective
· Eliminate the blocking/rough
running
· Replace step motor Z-axis
· Replace the control
2356
· Step motor Z-axis
excess temperature
· Step motor Z-axis
moves too heavy
· Step motor Z-axis defective
· Control defective
· Eliminate the rough running
· Replace step motor Z-axis
· Replace the control
2362
· Step motor Z-axis
IDMA Autoincrement
· Malfunction
· Switch the machine off
and on again
2911
-
2914
· Step motor fault
· Internal fault
· Switch the machine off
and on
again.
· Software update
· Inform DA-Service
3100
-
3103
· Machine voltage fault
· Short-term mains voltage dip
· Check the mains voltage and
stabilize, if necessary
3107
· Machine temperature
· Ventilation openings
closed
· Ventilation grids soiled
· Too high ambient temperature
· Check the ventilation openings
· Clean the ventilation grids
· Let the machine cool down
3221
-
3222
· Machine thread tension
regulator
· Internal fault
· Switch the machine off
and on
again
· Software update
· Inform DA-Service
66