3
4
To learn a sensor/remote control/TSR in selected memory space:
hold down the
P
button for 3 seconds
the
LED_X
or
LED_O
light on (depending on which one was already on): the receiver is now waiting
make the sensor * (only AN code, see sensor manual), the remote control or the TSR transmitter (only
disarming) transmit
the receiver confirms the learning of the code by blinking 2 times the
LED_A
, and emits 2 “beep”. The
LED_O
switches off but the
LED_X
(occupied memory)
5
After the Radio Zones for
Relay A
, there are the ones for
Relay B
(Radio Zones B-1 ÷ B-5).
The
LED_A
switches off and the
LED_B
lights on meaning the receiver is in memory space for Relay B.
The receiver starts from Radio Zone B-1. If the memory position is empty the
LED_O
(free memory) lights on,
if occupied the
LED_X
(used memory, it is possible to overwrite) lights on.
OR
6
To go to the next Radio Zone, press
P
.
As confirm the receiver emits as many “beep” as the Radio Zone number (Radio Zone B-2 = 2 “beep”, Radio
Zone B-3 = 3 “beep”…).
1x BEEP … 5x BEEP
7
To learn a sensor/remote control in selected memory space:
hold down the
P
button for 3 seconds
the
LED_X
or
LED_O
light on (depending on which one was already on): the receiver is now waiting
make the sensor * (only AN code, see sensor manual) or the remote control transmit
the receiver confirms the learning of the code by blinking 2 times the
LED_B
, and emits 2 “beep”. The
LED_O
switches off but the
LED_X
(occupied memory).
8
When finished to learn peripherals set
DIP1
to
OFF
*
Generally, to transmit an AN code press the TAMPER switch of the sensor. To learn the DSF (smoke) sensor, hold down the TEST button for some seconds. Read the manuals of each
product for further information.
4.
“S REMOTE CONTROLS” MODE
DIP1 = OFF | DIP3 = OFF | DIP4 = OFF
In this mode both sensors and remote controls work: the remote controls must be stored only in Relay A zones (Radio Zones A-1 ÷ A-5).
Set the working mode of the Relay A (for remote controls) with
DIP2
:
DIP2
=
ON
RELAY A BI-STABLE
The sensors must be stored only in Relay B zones (Radio Zones B-1 ÷ B-5).
By pressing the BIG button of a remote control, the Relay A is activated – pressing the SMALL button the Relay A releases
The Relay B is activated for 2 seconds when it is received an alarm code from a sensor stored in Radio Zones B
DIP2
=
OFF
RELAY A MON-OSTABLE
The sensors can be stored in both memory zones of Relay A and Relay B.
By pressing any button of a remote control the Relay A is activated for 2 seconds (then release)
The Relay B is activated for 2 seconds when it is received an alarm code from a sensor stored
5.
“REMOTE CONTROLS” MODE
DIP1 = OFF | DIP3 = OFF | DIP4 = ON
In this mode only the remote controls work: the remote controls must be stored only in Relay A zones (Radio Zones A-1 ÷ A-5). Do not store sensors (they will be ignored
by receiver). Set the working mode of the Relay A with
DIP2
:
DIP2
=
ON
BI-STABLE
By pressing once the BIG button of a remote control, the Relay A is activated – Pressing it again, the Relay A releases
By pressing once the SMALL button of a remote control, the Relay B is activated – Pressing it again, the Relay B releases
DIP2
=
OFF
MONO-STABLE
By pressing the BIG button of a remote control the Relay A is activated for 2 seconds (then release)
By pressing the SMALL button of a remote control the Relay B is activated for 2 seconds (then release)