2
2.
TECHNICAL
RELAY OUTPUTS
2 alarm relays (mono-stable or bi-stable working modes)
MAX: 24 V
/ 500 mA
SIGNALLING
Buzzer on board for operation feedback (not excludible)
4 internal LEDs for operation feedback (2 LEDs for relay outputs state, 2 LEDs for Radio Zones management)
RADIO RECEIVER
Working frequency: 433.92 MHz – Radio code format: 48 bit
POWER SUPPLY
12 V
/ MAX 25 mA
WARNING > The receiver must be powered by a very low voltage power source (SELV)
DIMENSION
120 x 85 x 28 mm
COMPATIBILITY
Sensors (only AN models): MINI-M, MINI-C, CTSR, DIRRV2, DIRRPV, DSA, DSF, E-WALL, DIRRVE, DIRRVE-DT, MOSKITO
Remote controls: TXS/M
Siren Transmitters: TSR
3.
LEARNING
LED_A
Yellow
LED_B
Green
LED_X
Blue
LED_O
Red
1
To enter in learning mode set
DIP1
to
ON
. Two “beep” are emitted
2x BEEP
2
LED_A
lights on meaning the receiver is in memory space for Relay A (Radio Zones A-1 ÷ A-5).
The receiver starts from Radio Zone A-1. If the memory position is empty the
LED_O
(free memory) lights on, if
occupied the
LED_X
(used memory, it is possible to overwrite) lights on.
OR
3
To go to the next Radio Zone, press
P
.
As confirm the receiver emits as many “beep” as the Radio Zone number (Radio Zone A-2 = 2 “beep”, Radio
Zone A-3 = 3 “beep”…).
1x BEEP … 5x BEEP
DIP1
OFF
Normal working
ON
LEARNING (pairing of radio devices)
DIP2
OFF
Relay A = Monostable
ON
Relay A = Bistable
DIP3
OFF
Normal working
ON
“LIGHT TIMER” mode
DIP4
OFF
“S Remote controls” mode or use with TSR
ON
“Remote controls” mode
+12
Power supply: positive ref12V
GND
Power supply: ground/negative reference
C1
Relay A: common terminal
NC1
Relay A: Normally Closed terminal
NA1
Relay A: Normally Opened terminal
C2
Relay B: common terminal
NC2
Relay B: Normally Closed terminal
LD
LED output: combined to Relay A activation
Output at +12V when the Relay A is active – Output at zero when Relay A is at rest.
Useful to visualize (using a TSR) the arming status of a control panel.
TMP
TAMPER output, Open Collector – Close to negative to signal the reception of a
tamper radio code from a sensor. In case of tamper alarm, also the Relay output
combined to the sensor will be activated.
LWB
LOW BATTERY output (sensors), Open Collector – Close to negative to signal the
reception of a Low Battery code from a sensor.