Page
iQ
Series
,
Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-583-00
LCD Display Overview
There are two basic kinds of screen displays:
Operate
screens, and
In Cycle
screens.
Figure 4-5
Example of an
In Cycle
Screen
IN CYCLE
Frequency: 40087 Hz
Power: 40 W
# 2
Status Indication
Stack Frequency
Power Draw
Power Bar Graph %
Figure 4-4
Example of an
Operate
Screen
Weld Mode -
Automation, Time,
or Energy
Automation Weld
Weld Time 0.500 S
Weld Energy 18 J
# 2
Data from
last weld
cycle.
Setup
number.
An
Operate
screen tells the operator
what happened in the last weld cycle.
An
In Cycle
screen activates when the ultrasound signal
has been activated.