Page 75
Dukane Manual Part No. 403-594-02
Section 6 - Options
AC Power Inlet Panel
The optional AC power inlet panel is described here.
AC Power Cord
An AC power cord is appropriately rated and can be per-
manently mounted at
A
in Figure 6-2 to the power inlet
panel.
Power Switch/Circuit Breaker
The power switch/circuit breaker (
B
in Figure 6-2) has a
rocker type actuator switch that will activate or deactivate
the AC power to the system. The power ON position is
marked with the internationally recognized I symbol, the
power OFF position is marked with the 0 symbol. This
power switch also integrates an appropriately sized over-
current protection circuit breaker function in the press.
If an over-current condition trips the circuit breaker, it
will automatically switch to the OFF position. If the over-
load current that caused the circuit breaker to trip is due
to a transient condition, the circuit breaker can be reset by
switching the actuator back to the ON position. If when
resetting the circuit breaker after it has tripped, it imme-
diately trips again, there is likely an internal system mal-
function that will require service.
Do not repeatedly try to reset the circuit breaker. If it trips,
this will only cause more damage to the press
Chassis Ground Stud
The chassis ground stud is used to attach a protective
earth ground to the generator. This will aid in the sup-
pression of electrical interference or radio frequency in-
terference (RFI) that is common in an industrial environ-
ment. The chassis ground stud is
C
in Figure 6-2. Proper
system grounding is discussed on Page 9.
Figure 6 - 2
120VAC Power Inlet Panel
A
B