Page 23
Section 3 – Installation
Dukane Manual Part No. 403-591-01
Connecting Cables
For stand-alone modules and securely installed panel
mounted modules:
Rear Connections
Refer to Figure 3-5 below. Complete these connections.
1. Earth ground - Connect one end of a user-supplied
14-Gauge ground wire to the ground connection at
the rear of the MPC -
A
in Figure 3-5. Connect the
other end of the wire to an earth ground potential at
the electrical box that supplies power to the equipment
(or to the equipment enclosure into which your system
is installed).
2. U/S (ultrasonic) cable (Dukane P/N 200-479-XXM -
Order the correct cable length for your installation.)
- Connect one end of the cable to the left rear U/S
connector of the MPC module -
B
in Figure 3-5. The
other end of the cable connects to J1 of the ultrasonic
generator.
3. MPC Interface cable (Dukane P/N 200-1408-XXM -
Order the correct cable length for your installation.)
- Connect one end of the cable to the right rear MPC
Interface connector -
C
in Figure 3-5. The other end
of the cable connects to the
MPC INTERFACE
con-
nector on the ultrasonic generator.
Figure 3-6
MPC Module Front Connectors
System Frequency
Probe P/N
Cable P/N : MPC to Probe
20kHz
41Q20RE or 41Q20RS
200-479-XXM
30kHz
41A60E or 41A60S
200-479-XXM
40kHz
41A40
200-615-XXM
Front Connections
Refer to Figure 3-6 below. Complete these connections.
1. Probe Cable(s) - Beginning with
PROBE 1
, connect
one end of the ultrasound cable (See Table 3-IV below.)
to the ultrasound connector on the MPC’s front panel
-
D
in Figure 3-6. Connect the other end of the cable
to the corresponding probe for your specific welding
application.
2. Repeat Step 1 for each of the remaining probes (in
sequence: 2, 3, 4, etc.) in your system.
Table 3-IV
Probe Cables
XX = length in meters
Figure 3-5
MPC Module Rear Connectors
D
B
A
C