MPC Module Status LEDs
System Status
The front panel
SYSTEM STATUS
LED
lights up
GREEN
when the system is powered and ready -
E
in Figure 3-7.
If this
LED
is lit with a
YELLOW/ORANGE
color, a
recoverable fault condition has tripped. This indicates
that the system is operational, but a fault condition has
occurred preventing normal operation. Examples of this
type of fault would be a generator overload that will
automatically reset when the next weld cycle begins,
or the automation control system is selecting a channel
that doesn’t exist - trying to select channel 10 for an 8
channel system, for instance.
If this
LED
lights up
RED
, a hardware fault has been
sensed, and the unit should be returned to Dukane for
servicing
.
Probe Selection Status
The
PROBE SELECTION STATUS
LED
-
F
in
Figure 3-7 -
lights up
GREEN
indicating it is the
selected probe.
A probe’s
LED
turns to
RED
(from
GREEN
) when
ultrasonic power is activated.
Figure 3-7
MPC Module Status LED’s
NOTE
Refer to
Section 4, System Operation
,
for more information.