Page 57
Section 1 – Introduction
Dukane Manual Part No. 403-591-01
iQ
Auto to
iQ
Auto Plus - Inputs/Outputs Comparison
iQ Auto
iQ Auto Plus
iQ Auto Plus Difference
System I/O Connector
P1 System I/O Connector
Pin
Signal Name
Pin
Signal Name
1
Enable Out
1
Enable Out
No difference.
2
Enable In
2
Enable In
No difference.
3
Overload Out
3
Overload Out
No difference.
4
U/S Status Out
6
U/S Status Out
Same function, but moved to Pin 6.
5
Any Fault Out
5
Any Fault Out
No difference.
6
Power OK Out
Removed.
7
Output Common
(non-isolated)
7
Output Common (isolated)
Isolated common - allows NPN or
PNP input operation.
8
Spare Status Out
Removed.
9
Analog Power Out+
Removed.
10
Analog Power Out-
Removed.
11
Fault Reset Input
Removed. (Faults automatically reset
at beginning of the next cycle.)
12
U/S Activate Input
13
U/S Activate
Same function, but moved to Pin 13.
13
Input Common
(isolated)
14
U/S Common (isolated)
Common for U/S Activate only.
Provides higher level of safety.
MPC I/O Connector
1
Setup Bit 0 Input
8
Remote Setup Bit 0 Input
Same function, but moved to single
I/O connector.
2
Setup Bit 1 Input
9
Remote Setup Bit 1 Input
Same function, but moved to single
I/O connector.
3
Setup Bit 2 Input
10
Remote Setup Bit 2 Input
Same function, but moved to single
I/O connector.
4
Setup Bit 3 Input
11
Remote Setup Bit 3 Input
Same function, but moved to single
I/O connector.
5
Input Common
(isolated)
12
Remote Common (isolated) Common for Remote Setup bits only.
Not tied to any other common.
6
MPC Ready Out
4
Ready Out
MPC Ready Output is incorporated
into the System Ready signal.
7
Output Common
Combined into P1 System I/O
Connector.
Table 8-II
iQ