RFI Grounding
In addition to the safety considerations previously men-
tioned, proper grounding at the generator power cord is
essential for the effective suppression of electrical noise
or RFI (Radio Frequency Interference). Every ultrason-
ic generator contains a RFI filter which blocks noise on
the AC power line from entering the system control cir-
cuitry. This filter also prevents ultrasonic frequency noise
from being fed back into the AC power line. In order for
the RFI filter to operate properly, it is necessary to cor
-
rectly ground the system. Run a grounding wire from the
grounding stud connection to the nearest grounded met-
al pipe or equivalent earth ground, and secure it with a
ground clamp.
See Figure 3-6 on Page 20.
CAUTION
To m i n i m i z e e l e c t r i -
cal noise and eliminate
ground currents, ground
the chassis as shown. Use
a STAR configuration (il
-
lustrated below). Do not
DAISY CHAIN the grounds.
Earth
Ground
#14 Gauge
Stranded or
Solid Wire
Fixed Probe Mount
or 2nd Chassis
Grounding Stud
3rd Chassis
Grounding
Stud
Chassis Grounding
Stud
Recommended
protective
earth ground connection
wire
color
: green or green
with yellow stripe.
Continent of Use
Power Cord
Part Number
Power
North America
200 - 1110
240V, 15A
200 - 1541
240V, 10A
Continental Europe
200 - 1111
240V, 16A
200 - 1542
240V, 10A