Twin Twist Soft Serve Freezer Model 957RMT
28
184957
9
Start-up Instructions
CAUTION
Mix Transfer System will
be pressurized during
operation. Make sure all
components and fasteners
are secure before start-up.
9.1
Sanitizing
The washing and sanitizing instructions
explained in this manual are important
procedures to remove bacteria and
maintain a clean, sanitary freezer. IDQ
requires the soft serve freezer to be
disassembled, washed, and sanitized
daily according to the instructions in
the manual. Always sanitize prior to
assembling to ensure the best possible
cleanliness.
IMPORTANT:
Do not use unapproved sanitizers
or laundry bleach. These materials
may contain high concentrations of
chlorine and will chemically attack
freezer components.
NOTE:
It is your responsibility to be
aware of and conform to the requirements
for meeting federal, state, and local laws
concerning the frequency of cleaning and
sanitizing the freezer.
1.
Prepare 2 gallons (7.5 liters)
of sanitizing solution for each
cylinder. Sanitizing solution must be
mixed according to manufacturer’s
instructions to yield 100 PPM strength
chlorine solution (example: Stera-
Sheen Green Label). Use warm water
(100° to 110°F or 37° to 43°C) to
wash, rinse, and sanitize.
2. Wash and sanitize your hands and
forearms.
3. Clean the interior mix tank walls, the
underside of the tank covers and low
mix probes with sanitizer liquid and
the appropriate brush provided.
4. Place the mix tank in the refrigerated
cabinet. Fill with sanitizing solution.
Important:
Never let the sanitizer remain in the
freezer for more than 15 minutes.
4. Immerse the pickup tubes into
the sanitizer solution and sanitize
the outside portion. If plastic mix
bag systems are used, be sure all
adapters and items that will come in
contact with mix are sanitized.
6. Place an empty container under the
dispensing head.
7. Open the air bleed plugs by pulling up
until the plugs touch the bottom of the
switch box.
8. Reconnect the main power supply
to the freezer. The spigots must be
closed. Place the MTS pump switches
to “ON”. This will push the sanitizer up
into the cylinders.
9. When sanitizer flows out the bottom of
the head, close the air bleed plugs.
Important:
DO NOT use the “AUTO” position
with sanitizer in the cylinder. The
freezer will be damaged.
10.
Place both selector switches to
“CLEAN” and allow the beaters to run
for 5 minutes. At this time check for
leaks around the head, drain tube,
clamps, and MTS.
11. Drain the solution from the cylinders
by slowly turning the spigot handles
open.
—continued
CAUTION
To prevent bacteria
growth, use only approved
sanitizers to sanitize
the machine. Sanitizing
must be done just prior
to starting the machine.
Failure to do so could
create a health hazard.
Summary of Contents for DQ 957RMT
Page 2: ......
Page 4: ......
Page 10: ...Twin Twist Soft Serve Freezer Model 957RMT viii 184957...
Page 62: ......
Page 64: ......
Page 76: ...Twin Twist Soft Serve Freezer Model 957RMT 12 184957 Figure 11 Back Side View sheet 1 of 2...
Page 82: ......
Page 83: ...Twin Twist Soft Serve Freezer Model 957RMT 184957 19 O Ring Chart...