Installation and Operation of: 

Refrigerated Counter RUF48 Digital

SERIAL NUMBER

Always have the serial number of your unit available when calling for parts or service.  The serial number can be found 

on the data plate inside the refrigerated compartment.

RECEIVING

 

&

 

INSPECTING

 

THE

 

EQUIPMENT

Care should be taken during unloading so the equipment is not damaged while being moved 

into the building. 

1.  Visually inspect the exterior of the package and skid or container.  Any damage should be noted and reported to 

the delivering carrier immediately. 

2.  If damaged, open and inspect the contents with the carrier. 

3.  In the event that the exterior is not dam¬aged, yet upon opening, there is concealed damage to the equipment 

notify the carrier. Notification should be made verbally as well as in written form. 

4.  Request an inspection by the shipping com¬pany of the damaged equipment. This should be done within 10 days 

from receipt of the equipment. 

5.  Check the lower portion of the unit to be sure legs/casters are not bent. 

6.  Also view compressor compartment housing and visually inspect the refrigeration pack¬age. Be sure lines are 

secure and base is still intact. 

7.  Freight carriers can supply the necessary damage forms upon request. 

8.  Retain all shipping material until an inspec¬tion has been made or waived. 

Figure. 2 

RUF 48

SPECIFICATIONS

Model

Volts Frequency 

(Hz)

Amps

Watts 

(Label)

HEIGHT

WIDTH

LENGTH

RUF-48 M

120

60

4.2

N/A

40.00 In. 29.50 In. 48.18 In.

RUF-48 M

220

60

2.7

590

40.00 In. 29.50 In. 48.18 In.

RUF-48 M

230

50

2.5

580

40.00 In. 29.50 In. 48.18 In.

Summary of Contents for RUF 48

Page 1: ...018 This manual is Copyright 2018 Duke Manufacturing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co CAUTION Please read this manual completely before attempting to install operate or service this equipment ...

Page 2: ...re Cleaning 6 Cleaning the Condensor Coil 7 Door Gasket Care 8 Drain Maintenance 8 Drain Pan Access 8 IMPORTANT WARNING AND SAFETY INFORMATION WARNING READ THIS MANUAL THOROUGHLY BEFORE OPERATING INSTALLING OR PERFORMING MAINTENANCE ON THE EQUIPMENT FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQU...

Page 3: ...ll Do not block the slots in the front kickplate Operate equipment only on the type of electricity indicated on the specification plate Retain this manual for future reference This publication contains information regarding the installation and operation of Duke Refriger ated Counter units The information contained within applies to the models RUF 48 Please read this manual completely before attemp...

Page 4: ...here is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by the shipping com pany of the damaged equipment This should be done within 10 days from receipt of the equipment 5 Check the lower portion of the unit to be sure legs casters are not bent 6 Also view compressor compartment housing and visually inspec...

Page 5: ... INSTALLATION Leveling Be sure that the units are placed on a firm flat surface floor Check for cracks in flooring or tile and avoid these areas if possible If necessary place support pads properly rated for the weight of the unit to bridge uneven or cracked flooring Level unit accordingly INSTALLATION Stabilizing Make sure the unit is installed on a flat surface to insure that the unit is solid to the...

Page 6: ...er the steels sur face which acts as a shield against corrosion As long as the protective layer is intact the metal will not corrode If the film is broken or contaminated outside elements can begin to breakdown the steel and begin to form rust or discolor ation Proper cleaning of stainless steel requires soft cloths or plastic scouring pads CAUTION Never use steel pads wire brushes or scrapers Clea...

Page 7: ...ndenser coil should be cleaned every 30 days Filter Condensing Coil is Located behind unit Figure 5 If the build up on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush heavier dust build up may require a vacuum or even compressed air to blow through the condensor coil If heavy grease is present degreasing agents are available for refrigeration u...

Page 8: ...into place MAINTENANCE Drain Each unit has a drain tube located in the rear the unit which removes condensation from the evaporator coil and deposits it onto a drain pan where it can evaporate If you notice excessive water accumulation on the inside of the unit be sure that the drain tube is connected from the evaporator hous ing to the condensate evaporator drain pan If water is collecting undern...

Reviews: