85
4. Check that the batteries are connected with the correct polarity to the charge
regulator and that any other connections are correct, tight and not corroded.
5.Fit a fuse tested to be good and of the correct size.
6. Switch on the refrigerator. (Some models also have circuit breaker protecting the
refrigerator, make sure that it is also switched on.)
7.Turn off the refrigerator, take out the fuse and check it.
If the fuse is:
-
Blown then PROCEED TO THE NEXT STEP ON THE FAULT FINDING CHART
to find out why the fuse is blowing.
DO NOT FORGET TO REPLACE THE FUSE LATER
-
Not blown, also PROCEED TO THE NEXT STEP ON THE FAULT FINDING
CHART. This is because the original fuse must have blown for a reason, and you
have to find the reason.