86
D5: LOW STATE OF CHARGE OF BATTERIES
THE BATTERIES MAY BE FAULTY OR MAY ONLY HAVE A LOW STATE OF
CHARGE as a result of a long period of cloddy weather.
SYMPTOMS OF THE FAULT
1 The refrigerator is too warm.
2 The voltmeter (not fitted to all models) shows battery voltage to be less than 11.5
V.
3.THE REFRIGERATOR DISCONNECTED indicator light is lit of has lit recently.
How to confirm fault
1.Cover the solar array so that NO sunlight falls on it.
2.Check that the refrigerator is switched ON.
3.measure the voltage of the batteries at the + and – terminals of the compressor
controller.
- The voltage should be greater than 11.5 volts for 12-volt systems (22.6
volts
for 24 volt systems) if the compressor is NOT running.
- The voltage should be greater than 10.5 volts for 12 volts systems (21.3
volts for 24 volt systems) if the compressor IS running.
4. If the voltage at the compressor controller terminals is not greater than the values
shown above, the batteries have a low state of charge.
Repair action required
1.
Switch off the regulator.
2.
If you have a fully charged replacement battery available (2 batteries for 24 volt
system) remove the battery from the refrigerator and connect the fully charged
battery.
Summary of Contents for VC150
Page 1: ......
Page 3: ...3 SECTION I ...
Page 4: ...4 ...
Page 24: ...24 MODULE AND BATTERY WIRING DIAGRAMS SYSTEM WIRING DIAGRAM ...
Page 25: ...25 SYSTEM WIRING DIAGRAM GENERAL LAYOUT DIAGRAM ...
Page 26: ...26 GENERAL LAYOUT DIAGRAM ELECTRICAL CIRCUIT DIAGRAM ...
Page 27: ...27 ELECTRICAL CIRCUIT DIAGRAM REFRIGERATION CIRCUIT DIAGRAM ...
Page 28: ...28 REFRIGERATION CIRCUIT DIAGRAM ...
Page 29: ...29 SECTION II ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 42: ...42 ...
Page 44: ...44 ...
Page 50: ...50 ...
Page 124: ...124 ANNEX 1 COMPONENT LAYOUTS OF SOME COMMONLY USED SOLAR REFRIGERATOR ...
Page 125: ...125 ...
Page 126: ...126 ...
Page 127: ...127 ...
Page 128: ...128 ...
Page 129: ...129 ...
Page 130: ...130 ANNEX II ADDITIONAL EPI TOOL KIT NEEDED FOR PHOTOVOLTAIC REFRIGERATOR REPAIR ...
Page 136: ...136 ...
Page 137: ...137 ...