www.factorybuysdirect.com
5
200257-01A
QUALIFIED INSTALLING AGENCY
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term “qualified agency” means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This stove has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system.
The ODS/pilot shuts off the stove if there is
not enough fresh air.
PIEZO IGNITION SYSTEM
This stove is equipped with an electronic piezo
control system. This system requires one AAA
battery (provided).
THERMOSTATIC CONTROL
The control automatically cycles the burner
on and off to maintain a desired room tem-
perature.
2 GAS OPTIONS AVAILABLE
Your stove is equipped to operate on either
Propane/LP or Natural gas. The stove is
shipped from the factory ready for connect-
ing to Propane/LP. The stove can easily be
changed to Natural gas by having your quali-
fied installer follow the instructions on page
10 and the markings on the stove.
MANUAL OVERRIDE CONTROL
SYSTEM
This stove has two operation functions. Re-
mote Control and Manual Override Control.
The remote control has a transmitter, which
requires two AAA batteries and electric power
outlet to operate. In the event of a power
outage, you can operate the the stove by
manual override.
LOCAL CODES
Install and use stove with care. Follow all local
codes. In the absence of local codes, use the
latest edition of
The National Fuel Gas Code,
ANSI Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This stove is designed for vent-free operation.
State and local codes in some areas prohibit
the use of vent-free stoves.
State of Massachusetts:
The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a flexible
appliance connector cannot exceed three
feet in length.