background image

 

PRODUCT FEATURES  

 

 

• 

Built-in or Free-standing installation with single, dual 
or  three  temperature  zone,  depending  on  your 
model. 

 

 

• 

Continuously variable electronic temperature control 
with digital display and touchpad input.

 

 

• 

Temperatu

re can be set from 5° to 20°C (41° to 68°F 

)***** for either compartment and can be displayed in 
either Fahrenheit or Celsius.

 

 

• 

Can  be  set  to  the  long  time  storage  maturing 
temperature  or  a  specific  serving  temperature  for 
red/white/sparkling wines.

 

 

• 

Cooling  and  Heating  (for  particular  items  only)  to 
maintain  the  perfect  storaging  and/or  service 
condition.

 

 

• 

Dynamic compressor type cooling to ensure interior 
air  circulation  with  even  distribution  of  temperature 
and humidity.

 

 

• 

Soft  LED  Interior  Light  with  ON/OFF  switch 

– 

Function mode  and Showcase mode.   Open-door 
and malfunction warning system (for particular items 
only)

 

 

• 

Sabbath  mode  will  allow  the  lights  to  remain  off 
during  certain  religious  observances  (for  particular 
models only).  

• 

Temperature  memory  function  -  If  power  is 
interrupted  (power  surge,  breaker  switch,  etc.)  and 
then powered up again, the unit will operate with the 
last temperature set-point. for particular  
models only)  

• 

Automatic defrosting with defrost water evaporation.

 

 

• 

Reversible  tempered  double/triple  pane  glass  door 
protects  your  wine  from  UV  light  and  creates  an 
attractive  display  with  few  condensation  and  low 
noise.

 

 

• 

Black  coated  matte  steel  outer  frame  and  black 
plastic  interior  liner  offer  lifetime  performance  and 
stability. The black liner prevents excessive light from 
damaging  the  maturity  process.

 

  Full  glass  or 

seamless  stainless  steel-framed  glass  door  with 
stainless steel handle.

 

 

• 

Beech shelves allow for maximum convenience and 
flexibility  to  accommodate  various  size  bottles 
(except  DX-7.20  models).

 

  Security  lock  system 

with keys (for particular items only).

 

 

• 

Passive  humidity  control  system  (Humidity  Box).

 

 

Active charcoal air filter (for particular items only).

 

 

  

NOTE:

  Features  and  specifications  are  subject  to 

change without notice.  

  

INSTALLATION  

 

 

BEFORE USING YOUR APPLIANCE  

  
•  Remove  all exterior  and interior packing. Clean the 

interior  surface  with  lukewarm  water  using  a  soft 
cloth. The unit may have residual odors at first, they 
will disappear as the unit cools.  

  
•  Before connecting the appliance to the power source, 

let  it  stand  upright  for  at  least  24  hours.  This  will 
reduce the possibility of a malfunction in the cooling 
system  caused  by  handling  during  transportation. 

During  this  time  we  recommend  that  you  leave  the 
door open to clear any residual odors.  

  
•  The door on this appliance can be opened from either 

the left or the right side. The unit is delivered with the 
door  opening  on  the  left  side.  Should  you  wish  to 
open the door from the right, follow  the instructions 
‘Reversing  the  door  hinge’Install  the  handle  on  the 
door if necessary.  

  

INSTALLATION OF YOUR APPLIANCE  

 

 

•  The  appliances  are  designed  to  be  built-in  or 

recessed or free standing installation.   

  
• 

WARNING:

  Do  not  store  or  install  the  appliance 

outdoors. The unit is for indoor use only.  

 

 

• 

WARNING:

  Do  no  install  the  appliance  in  the 

laundry. Avoid locating the unit in damp areas.  

  
•  Place your appliance on a floor that is strong enough 

to  support  it  when  it  is  fully  loaded.  Remove  the 
transport legs before installation. Fix installation legs 
(packed to your user manual) if you need to level the 
unit only.   

  
•  For  freestanding  installation,  100mm  of  space 

between  the  back  and  sides  of  the  unit  are 
suggested, which allows the proper air circulation to 
cool  the  compressor  and  condenser  for  energy 
saving.  Even  for  built-in  installation,  it  is  a  must  to 
keep  5mm  space  on  each  side  and  at  the  top  to 
ensure  proper  service  access  and  ventilation.  Take 
care  that  the  air  vent  at  the  front  of  the  appliance 
must never be covered or blocked in any way.   

  
•  Locate the unit away from direct sunlight and sources 

of heat (stove, heater, radiator, etc.). Direct sunlight 
may affect the acrylic coating and heat sources may 
increase  electrical  consumption.  Extreme  cold 
ambient temperatures may also cause the unit not to 
perform properly. 

 
•  Plug the unit into an exclusive, easily accessible plug 

socket.  Any  questions  concerning  power  and/or 
earthing  should  be  directed  towards  a  qualified 
electrician or an authorized products service centre.  

  
•  The  appliance  must  be  installed  to  all  electrical, 

connections  in  accordance  with  state  and  local 
codes.  

  
• 

IMPORTANT:  HIGH  HUMIDITY  CLIMATE.

  During 

periods  of  high  humidity,  some  condensation  may 
appear  on  outside  surfaces  of  glass  door.  This 
condensation  will  disappear  when  humidity  levels 
drop.  For  prevention,  it  is  advisable  to  install  the 
appliance with sufficient ventilation in a dry and/or an 
air-conditioned place.   

 

 

NOTE: The appliance must be positioned so 
that the plug is accessible.   

  

Summary of Contents for DAUF-16.52

Page 1: ...rn to its initial position after 3 seconds automatically And the unit will beep once again and it is ready for next opening action NOTE The door will close again automatically after approx 3 seconds if it has not been fully opened manually for models with automatic door closing function Do not block the door or hold on it while it is opening If the door is blocked or held during opening the door o...

Page 2: ...centre or similarly qualified persons in order to avoid a hazard The use of attachments not recommended by the manufacturer may be hazardous Place the unit on a dry level surface Do not operate if the housing is removed or damaged A loose fit between the AC outlet receptacle and plug may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn outlet ...

Page 3: ... disconnect the appliance from the power supply before servicing SAVE THESE INSTRUCTIONS If you are experiencing problems check the Troubleshooting Guide at the back of this manual It lists causes of minor operating problems that you can correct by yourself DISPOSAL Dispose of your appliance packaging properly Ensure that any plastic wrappings bags etc are disposed of safely and kept out of the re...

Page 4: ...ource let it stand upright for at least 24 hours This will reduce the possibility of a malfunction in the cooling system caused by handling during transportation During this time we recommend that you leave the door open to clear any residual odors The door on this appliance can be opened from either the left or the right side The unit is delivered with the door opening on the left side Should you...

Page 5: ...ult in the risk of electrical shock If the power cord is damaged have it replaced by a qualified electrician or an authorized service center All electrical work should be carried out by a suitably qualified and competent person in accordance with local and national safety regulations Check that the voltage marked on the product corresponds with your supply voltage Connect this appliance to a separ...

Page 6: ...lock on the ventilation grille Fig 4 7 Rotate the door 180 No need for models with lock on the door and relocate the door to the designated position Then screw the bottom hinge assembly on the left designated position and tighten it after the door is leveled 8 Transfer the handle plugs to the opposite positions if need DESIGN 2 For fully integrated models 1 Remove the glass door by unscrewing the ...

Page 7: ...amage Then remove the right top hinge 10 Fig 5 4 4 Unscrew and transfer the middle hinge 12 and the middle fixing plate 11 to the opposite position Fig 5 5 Pop out the cover caps on the left side of cabinet and use them to cover the screw holes on the right hand side 6 Screw the alternative left top hinge 9 included in the fittings on the left hand side of cabinet Fig 4 7 Relocate the door adapter...

Page 8: ...crease cool the set temperature by 1 C 1ºF Display Display the digital temperature and service indicators Indicator Light The indicator light is located at the right lower corner of the display The indicator light will be on when the multi key function is selected To perform the multikey function press and hold the first key then press the other key for at least 5 seconds and then release all the ...

Page 9: ...ng white and red wine at a setting of 13 C to 20 C 55 F to 68 F The UPPER LEFT temperature zone is suitable for storing champagne and white wine at a setting of 5 C to 13 C 41 F to 55 F When the unit is plugged in for the first time the unit will power up automatically to the preset defaults The preset temperature at the factory for UPPER LEFT temperature zone is 10ºC 50ºF and for LOWER RIGHT temp...

Page 10: ... The display flashes while you make the setting After the temperature has been set the display shows the current inner temperature of the particular temperature zone To view the set temperature at any time press the UP or DOWN key the set temperature will temporarily flash in the display for 5 seconds Then the display shows the current inner temperature again TEMPERATURE DISPLAY During normal oper...

Page 11: ...r wine bottles in single row or by stacking while taking note of the following if you do not have enough bottles to fill your wine cellar it is better to distribute the load throughout the wine cellar so as to avoid all on top or all below type loads Do remove or relocate adjustable wooden racks to accommodate larger type of bottles or increase the capacity of the cellar by stacking the bottles up...

Page 12: ...olant circulating in the system is unavoidable DEFROSTING HYGROMETRY VENTILATION Your unit is designed with an automatic defrost system During the Off cycle the evaporator behind the rear wall of the unit defrosts automatically The condensate collects in the drain trough behind the rear wall of the unit and part of it flows through the drainage hole into the drip tray by above the compressor The h...

Page 13: ...ker switch etc and then powered up again the unit will operate with the last temperature set point Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If the power is going to be off for a longer period of time you need to take the proper steps to protect your contents NOTE Irrespective ...

Page 14: ...en The door is not closed completely The door gasket does not seal properly Put the appliance in a cooler place Leave the appliance to work for a while until the set temperature has been reached Do not open the door more often than necessary Close door properly Check the door seal and clean or replace The light does not work Appliance is not connected to a power supply The circuit breaker tripped ...

Page 15: ...reached The icon is lit up and flashing in the temperature display The display temperature is out of the range Only temperatures within the range 0 99 F 9 37 C the appliance can display will be shown If the temperature is not within this range the icon will be displayed instead That is normal WARRANTY The warranty does not cover 1 Damage in transit or when moving the appliance 2 Any damages caused...

Reviews: