10
Instruction Manual/Betriebsanleitung
BG 65 SI
, Version: 1.3 en_de
© 2010 Dunkermotoren GmbH; D-79848 Bonndorf; Germany
5.2 Mechanical data
Temperature range
motor
-20 °C ... +100 °C
housing temperature
Recommended environ-
mental temperature range *) 0 °C ... 50 °C
Relative humidity
(not condensing)
Max. 90%
Protection class **)
IP50 (in special versions
up to IP65)
Connector plug
12-pole ***)
Round connector accor-
ding DIN 45326, compa-
ny Binder, series 723
*) The motor is specified for an ambient temperature
of 20°C. The performance data refer to this ambient
temperature.
**) The protective system only refers to the motor /
gearbox casing. The shaft is to be sealed by the client.
The drive may only be used in an environment comply-
ing with IP54 if the shaft outlet has been installed such
that it is protected from dust and water.
***) Please see the pin diagram for further information.
5.3 Dimensions
5.2 Mechanische Daten
Temperaturbereich
Motor
-20°C…+100°C
Gehäusetemperatur
Empfohlener Umge-
bungstemperaturbereich *)
0°C…50°C
Relative
Luftfeuchtigkeit
Max. 90%
Schutzart **)
IP 50 (in Sonderaus-
führungen bis IP 65)
Anschlussstecker
12-polig ***)
Rundstecker nach
DIN 45326, Firma
Binder, Serie 723
*) Der Motor ist für eine Umgebungstemperatur von
20°C spezifiziert. Die Leistungsangaben beziehen sich
auf diese Umgebungstemperatur.
**) Die angegebene Schutzart bezieht sich nur auf das
Motor- bzw. Getriebegehäuse. Die Abdichtung der Welle
ist vom Kunden vorzunehmen. Nur wenn der Wellenau-
stritt staub- und wassergeschützt montiert wird, kann der
Antrieb in einer Umgebung entsprechend IP54 einge-
setzt werden.
***) Weitere Informationen finden Sie im Abschnitt An-
schlussbelegung.
5.3 Motormasszeichnung
Summary of Contents for BG 65 SI
Page 37: ...Notes Notizen ...
Page 38: ...Notes Notizen ...