9
Instruction Manual/Betriebsanleitung
BG 65 SI
, Version: 1.3 en_de
© 2010 Dunkermotoren GmbH; D-79848 Bonndorf; Germany
5 Technical data, accessories
5.1 Electrical data
Maximum motor speed
range
0 ... 7000 U/min
Speed range
adjustable
70 ... 4096 U/min
Minimum motor
voltage
20 V DC
Maximum motor voltage
at 24 V-version
30 V DC
Maximum motor voltage at
42 V-version
50 V DC
Maximum ripple on
supply voltage
Max. 5 %
Undervoltage shutdown
< 19 V
Demolition boundary
at 24 V- version
> 35 V
Demolition boundary
at 42 V- version
> 55 V
Required
external fuse
8 AT external
Over-temperature
protection
103°C at the
power output stage
Max. peak current
(motor)
27 A
Current consumption
of 24 V-logic supply
*)
40 mA (only motors
with 42 V- or 60 V-
operating voltage)
*) This value is only correct without using of an encoder
and when the digital outputs are unloaded. Additional
components connected to the outputs increase the current
consumption.
5 Technische Daten, Zubehör
5.1 Elektrische Daten
Ungeregelter
Drehzahlbereich
0 ... 7000 U/min
Regelbarer Drehzahl-
bereich
70 ... 4096 U/min
Minimal zulässige
Motorspannung
20 V DC
Maximal zulässige
Motorspannung
bei 24 V-Ausführung
30 V DC
Maximal zulässige
Motorspannung
bei 42 V-Ausführung
50 V DC
Zulässige Restwelligkeit
der Versorgungsspannung
Max. 5 %
Unterspannungsabschaltung < 19 V
Zerstörungsgrenze
bei 24 V-Motoren
> 35 V
Zerstörungsgrenze
bei 42 V-Motoren
> 55 V
Absicherung
8 AT extern erforder-
lich
Übertemperaturabschal-
tung
103°C an der
Leistungsendstufe
Max. Spitzenstrom
(Wicklung)
27 A
Stromaufnahme
der 24 V-Logikversorgung*
)
40 mA (nur bei Mo-
toren mit 42 V- oder
60 V-Betriebsspan-
nung)
*) Dieser Wert gilt nur bei Betrieb ohne zusätzlichen
Drehgeber und unbelasteten digitalen Ausgängen. Eventuell
an den Ausgängen angeschlossene Komponenten erhöhen
den Strombedarf entsprechend.