128
c
Platemaking/Master Feed and Ejection Section
chap.3
1) Remove the master feed unit.
2) Remove the 4 screws.
3) Remove the bush indicated, and remove the
mater feed stepping motor.
(5) Removal of Master Feed Stepping Motor
Screws
Master feed stepping motor
440056
440057
12) Remove the bundle wire from the 2 connectors
of the thermal head and the clamp.
13) Close the master cover.
14) Disconnect the 4 connectors.
15) Remove the 6 screws indicated, and remove the
master feed unit.
\
See page 127
Master feed unit
1) Open the document receiving tray, and take out
the master roll.
2) Take out the drum unit.
3) Remove the front cover.
\
See page 112
8) Remove the 2 covers shown in the figure.
9) Disconnect the 2 connectors indicated.
10) Open the master cover.
11) Remove the guide plate.
\
See page 127
(4) Removal of Master Feed Unit
Cover R
Screw
Screw
Screw
Connectors
Connectors
440084
Screw
Switch bracket
4) Remove the scanner side cover L.
5) Remove the side cover L.
6) Remove the 2 screws indicated, and remove the
cover L.
7) Remove the 3 screws indicated, and remove the
switch bracket.
\
See page 115
\
See page 113
Screws
Screws
Screw
Screw
Screws
Summary of Contents for Duprinter DP-330
Page 9: ......
Page 11: ......
Page 18: ...c Dimensions chap 1 17 MEMO...
Page 24: ...4 8 2A 2B 2C 44000A1e b Part Names and Their Functions chap 1 23...
Page 152: ...151 MEMO...
Page 193: ...192 MEMO...
Page 329: ...328 x Overall Wiring Layout chap 8 15 Overall Wiring Layout 2 Drive PCB 2 2...