DBM70 Instruction ver 1.doc
Page 13
3/12/01
6.
COUNTER
The counter can be reset to '0000' by pressing the rectangular black button below the number
window.
7. REPLACING STAPLING HEADS
Should it become necessary to remove either or both of the stapling heads follow the procedure
below.
10.
Pull the left-hand side of the spring clip so that the eye clears the pin and swivel the spring
clip anti-clockwise around the actuating bar. This should remove the hook on the right-hand
side of the clip from the other end of the pin.
11.
Unplug the electrical lead from the bracket containing the reset button and lights.
12.
Loosen the small (M6) bolt in the stapling head retaining plate sufficiently so that the
retaining plate can be lifted and pushed aside revealing the trough in which the bar at the
back of the stapling head is located.
13.
Take the bar from the trough and having removed the head completely replace the retaining
plate in it’s original position and tighten the bolt.
14.
To re-fit a new head place the bar at the back of the stapling head into the trough, position
the retaining plate over the top and tighten the bolt and replace the spring clip. Replace
electrical lead.
8. ADJUSTMENT GUIDE FOR SWINGLINE STAPLER
If you find the stapling head is giving a bad staple, re-align the head. The instructions that follow are
a guide to help re-align the heads.
Unplug the machine then:
1.
Remove cassette of staples from stapler.
2.
Loosen the hex screws holding part no. 2.105
3.
Place the adjustment guide between the stapler and anvil. Align and insert the raised lugs of
the guide into the underside of the stapler where the staple exits, making sure the metal
locating pip is to he front. When inserted replace the cassette of staples.
4.
Locate pip on adjustment guide into small hole at front of anvil and then retighten hex
screws. The stapling head should now be in a position to carry in stapling after removing
adjustment guide.