EWM-2SS-DAD/22E-PN
89475/119 ETM
Duplomatic MS
▪
EWM-2SS-DAD/22E-PN Start-up Manual
–
89475-PN/119 ETM --- Mar 2019
47
Description of the status byte 2:
Nr.
Bit
Name
Description
Type
Default
1
0
Senserror_2
Sensor error.
Monitored are SSI and 4… 20 mA input signals.
Attention
: Inverted signal, an error exists if the bit is
not
set
.
BOOL
0
2
1
-
-
BOOL
0
3
2
-
-
BOOL
0
4
3
-
-
BOOL
0
5
4
-
-
BOOL
0
6
5
Poswin_2:D
Dynamic position monitoring.
Message for being within the preset window for following error
in NC mode.
BOOL
0
7
6
Poswin_2:S
Static position monitoring.
Message for reaching the target position within the preset
tolerance (SDD mode).
BOOL
0
8
7
Ready_2
General operational readiness of the axis.
ENABLE signals are available and no error was detected.
BOOL
0
Description of the status byte 3:
Nr.
Bit
Name
Description
Type
Default
1
0
-
-
BOOL
0
2
1
-
-
BOOL
0
3
2
-
-
BOOL
0
4
3
-
-
BOOL
0
5
4
-
-
BOOL
0
6
5
BufferOV
BufferOverflow data overflow.
Attention
: Inverted signal, an
error exists if the bit is
not
set
.
BOOL
0
7
6
Chkerror
Error in the checksum of the EtherCAT data transferring.
Attention
: Inverted signal, an error exists if the bit is
not
set
.
BOOL
0
8
7
Derror
Internal data error.
Attention
: Inverted signal, an error exists if the bit is
not
set
.
BOOL
0
Description of the status byte 4:
Nr.
Bit
Name
Description
Type
Default
1
0
LIVEBIT_OUT
Feedback (= LIFEBIT), monitoring of communication
BOOL
0
2
1
-
BOOL
0
3
2
-
BOOL
0
4
3
-
BOOL
0
5
4
-
BOOL
0
6
5
-
BOOL
0
7
6
PARA_READY
Parameter has been taken over
BOOL
0
8
7
PARA_ACTIVE
Bus parameterization
BOOL
0