AC receptacles
This generator is equipped with the following receptacles:
5-20R:125 Volt, 20 Amp Duplex Receptacles (NEMA)
You can use the receptacle to operate 120 Volt AC, single-phase, 60Hz electrical loads that
require up to a maximum of 2,400 watts (1.8 kW) at 20 Amps of current or greater.
Use only power cords rated for 125 Volt AC loads at 15 Amps, or greater.
L5-30R: 120Volt, 30Amp Twist Lock Receptacle
Use this receptacle to operate 120 Volt AC, single-phase, 60 Hz electrical loads that
require up to a maximum of 3,600 watts (3.6 kW) at 30 Amps of current or greater.
Use only power cords rated for 125 Volt AC loads at 30 Amps, or greater.
L14-30R: 240/120Volt, 30Amp Twist Lock Receptacle
Use this receptacle to operate 240/120 Volt AC, single-phase, 60 Hz electrical loads that
require up to a maximum of 6,500 watts (6.5 kW) at 27 Amps of current or greater for the
DG66M series models and 7000 watts (7.0 kW) at 29 amps for the DG67M series models.
Use only power cords rated for 125/250 Volt AC loads at 30 Amps, or greater.
5 L5-30 RECEPTACLE
17 CHOKE
6 MAIN BREAKER
18 TANK
7 ALTERNATOR
19 FUEL TUBE
8 GROUND TERMINAL
20 CHECK VALVE
9 FOOT
21 FUEL TANK CAP
10 LOW OIL LAMP
22 HOUR METER
11 OIL FILLER CAP
23 MUFFLER COMP
12 NUT
24 L14-30 RECEPTACLE
Summary of Contents for DG66M-B62
Page 7: ...5 P a g e DG66M R62 B62 DG67M R62 B62 Generator Safety Labels...
Page 9: ...7 P a g e DG66M R62 B62 DG67M R62 B62 Generator Operating and Battery Safety Labels...
Page 42: ...40 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG66M R62...
Page 43: ...41 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG66M B62...
Page 49: ...47 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG67M R62...
Page 50: ...48 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG67M B62...