29 |
P a g e
DG66M-R62, -B62 & DG67M-R62, -B62
Starting the Generator
1. Perform the Pre-Operation Check (page 25-30.)
2. Confirm that no appliances are connected to your generator’s AC
receptacles
3. Turn the Fuel Valve to ON position
4. If the engine is cold, move the Choke Lever to on position as
shown by the arrow.
If the engine is warm, move the Choke Lever to the closed/off
position.
5. Start the Generator Engine:
(Refer to the engine owner’s manual for more details on starting
the engine)
If you have electric start models (DG66M-B62 and DG67M-B62):
Turn the key to start position momentarily until it starts:
If your generator does not have a battery, models (DG66M-R62 and DG67M-R62)
:
Push the switch to the “ON” position:
Pull the Starter Grip
gently until you feel slight resistance, then pull briskly.
Warning:
Avoid damaging the starter and its housing.
Don’t let the Starter Grip snap back into place.
Gently guide it back into position.
For safety, do not operate your generator indoors or in partially enclosed areas.
The generator’s exhaust contains toxic carbon monoxide gas and can collect
rapidly in even partially enclosed areas such as a garage.
Breathing this poisonous gas can cause severe illness and even death.
Summary of Contents for DG66M-B62
Page 7: ...5 P a g e DG66M R62 B62 DG67M R62 B62 Generator Safety Labels...
Page 9: ...7 P a g e DG66M R62 B62 DG67M R62 B62 Generator Operating and Battery Safety Labels...
Page 42: ...40 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG66M R62...
Page 43: ...41 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG66M B62...
Page 49: ...47 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG67M R62...
Page 50: ...48 P a g e DG66M R62 B62 DG67M R62 B62 Wiring diagram DG67M B62...