The replacement of the Shutter block and the UV Cell is to be done in the following manner:
1. Disconnect the scanner cable.
2. Remove the cover (4 x M3) and the housing (4 x M5 – Allen screws).
With Ex-type units there are special instructions for opening the housing, which are detailed in
the chapter “Installation of Scanners with Explosion-proof housings.”
3. Remove the electronics assembly from the upper housing.
4. Remove the Shutter block.
5. Remove the cable connectors and reconnect them to the replacement unit. Please note the
polarity.
6. Assemble the shutter block.
7. Screw the electronics assembly back onto the housing. Pay attention to the asymmetrical
countersinking in the upper housing. The shutter block should lay open in the countersinking.
8. Assemble the electronics assembly and the housing, making sure not to crimp the wires.
9. Replace the cover.