5.1.2. Multi-Brand ON/OFF filter pump wiring instructions
Ensure the advised cable sections are adhered to when connecting the
Multi-Brand ON/OFF filter pump.
The designated connection terminal blocks need to be used to connect the
Multi-Brand ON/OFF filter pump to the LINK Master. Ensure the screws are
firmly tightened!
DLM-600 filter pump wiring
5.1.3. Multi-Brand Inverter filter pump wiring instructions
Ensure the advised cable sections are adhered to when connecting the
Multi-Brand Inverter filter pump.
The designated connection terminal blocks need to be used to connect the
Multi-Brand Inverter filter pump to the LINK Master. Ensure the screws are
firmly tightened!
The Multi-Brand Inverter filter pump wiring is pump specific! And should be
done by a qualified electrician. As additional wires need to be connected to
select boost by using the available Relay A on the LINK Master.
The Multi-Brand Inverter filter pump should be wired and configured to
support the following controls:
•
When Relay A is open (not activated): the Multi-Brand Inverter filter
pump should be programmed to run at a fixed normal speed.
•
When Relay A is closed (activated): the Multi-Brand Inverter
filter pump should run at a fixed maximum speed
.
Be aware that the available LINK Master connections for Multi-Brand
devices are limited and therefor present restrictions. For example;
using Relay A for the Multi-Brand Inverter filter pump, restricts also
using the LINK Master for the connection of a Multi-Brand cover.
They cannot be combined.