SIDE SEALER SETUP MENU
This screen accesses the Side Sealer Setup Timers.
Press the RECTANGULAR BUTTONS to access the desired Timer.
SIDE SEALER “ON” DELAY TIMER MENU
The Side Sealer “ON” Delay Timer is controlled by this screen. This timer controls the Time Delay before
the Side Sealer Solenoid turns on. The timer starts timing when the bag stops advancing and the Fill Opening
has opened.
The time can be adjusted by Pressing the TOP RECTANGULAR BOX and entering the time on the numeric
key pad or by Pressing the UP / DOWN ARROWS.
•
Note: The time range is 0.20 seconds to 0.40 seconds.
The average bags per minute is displayed in the Bottom Rectangular Box.
Press the RETURN Button to go back to the Setup Menu.