Rev.4
10
SIDE SEALER “OFF DELAY TIMER MENU
The Side Sealer “OFF” Delay Timer is controlled by this screen. This timer controls the length of time that
the Side Sealer Solenoid stays on.
The time can be adjusted by Pressing the TOP RECTANGULAR BOX and entering the time on the numeric
key pad or by Pressing the UP / DOWN ARROWS.
•
Note: The time range is 0.10 seconds to 1.50 seconds.
The average bags per minute are displayed in the Bottom Rectangular Box.
Press the RETURN Button to go back to the Setup Menu.
LOW ICE DELAY TIMER MENU
The Low Ice Delay Timer is controlled by this screen. This timer controls the length of time that the
Volumetric will continue to run after a low ice condition is detected.
The time can be adjusted by Pressing the TOP RECTANGULAR BOX and entering the time on the numeric
key pad or by Pressing the UP / DOWN ARROWS.
•
Note: The time range is 1.00 second to 5.00 seconds.
The average bags per minute are displayed in the Bottom Rectangular Box.
Press the RETURN Button to go back to the Setup Menu.